SU‐FF‐T‐218: Evaluation of the Exradin #a19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams

2007· article· en· W2028299871 on OpenAlexaboutno aff
M McEwen

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldAgricultural and Biological Sciences
TopicRadiation Effects and Dosimetry
Canadian institutionsnot available
Fundersnot available
KeywordsIonization chamberDosimetryPhysicsOpticsCalibrationIonBeam (structure)PhotonMaterials scienceAtomic physicsNuclear medicineIonization

Abstract

fetched live from OpenAlex

Purpose: The Exradin #a19 is a new design of reference‐class 0.6cc ion chamber that externally resembles the NE2571 Farmer chamber but internally is very similar to the well‐known Exradin #a12. This project involved the characterization of a single version of this chamber in high energy x‐rays. Method and Materials: The Exradin #a19 was compared against primary and reference standard ion chamber chambers at the National Research Council of Canada in a range of megavoltage photon beams (6–25 MV). Investigations looked at chamber settling, ion recombination and polarity, and determination of experimental k Q factors. Results: Chamber settling — the chamber response stabilizes very quickly (within 5 minutes), even after a large change in the polarizing voltage. i) The polarity correction was measured for 6 MV and 25 MV beams and found to be small (within 0.15% of unity). ii) The recombination correction showed a linear variation with the dose‐per‐pulse. The correction was similar to that of other Farmer‐type chambers. iii) Beam quality conversion factors were found to be closer to that of the NE2571 than the #a12, which is not consistent with the guidance given in TG‐51. However, with only a single chamber under investigation one cannot draw any definitive conclusions. Conclusion: An initial investigation of the Exradin #a19 Farmer‐type ion chamber suggests that it is fit for purpose for the calibration of megavoltage photon beams. Further work is in progress to evaluate this chamber in kilovoltage x‐ray and high‐energy electron beams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.841
Threshold uncertainty score0.225

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.294
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Effects and DosimetryFrench-language works237,207