MétaCan
Menu
Back to cohort
Record W2029028610 · doi:10.1373/clinchem.2009.124743

A Commutable Cytomegalovirus Calibrator Is Required to Improve the Agreement of Viral Load Values between Laboratories

2009· article· en· W2029028610 on OpenAlexaff
Angela M. Caliendo, Mona D Shahbazian, Carl Schaper, Jessica Ingersoll, Deborah Abdul-Ali, Jerry Boonyaratanakornkit, Julie D. Fox, Jutta K. Preiksaitis, E. Ralf Schönbrunner

Bibliographic record

VenueClinical Chemistry · 2009
Typearticle
Languageen
FieldMedicine
TopicCytomegalovirus and herpesvirus research
Canadian institutionsProvincial Laboratory of Public Health
FundersNational Institute of Allergy and Infectious DiseasesCenter for AIDS Research, University of WashingtonEmory University
KeywordsViral loadCalibrationMedicineStatisticsVirologyHuman immunodeficiency virus (HIV)Mathematics

Abstract

fetched live from OpenAlex

BACKGROUND: Viral load testing for cytomegalovirus (CMV) is an important diagnostic tool for the management of transplant recipients and immunocompromised individuals; however, inconsistency among laboratories in quantitative measurements of viral load limits interinstitutional comparisons. These inconsistencies stem from the lack of assays cleared by the US Food and Drug Administration, the absence of international standards, the wide variety of CMV-extraction and -detection methods, and differences in materials used for calibration. A critical component of standardization is the use of calibrators that are traceable and commutable. METHODS: Bland-Altman plots and prediction ellipses were used to test the commutability of 2 CMV calibrators for 2 different quantification methods. RESULTS: Tests with 2 methods showed 1 calibrator to be commutable and the other to be noncommutable. The results for the commutable calibrator were within the 95% prediction interval of the clinical samples in the Bland-Altman plot and within the 95% prediction ellipse for a simulated commutable calibrator, whereas the results for the noncommutable calibrator were not within these prediction intervals. When used to calibrate patient results, only the commutable calibrator, the OptiQuant CMV(tc) Calibration Panel, significantly improved the comparability of viral loads for the 2 different measurement methods. CONCLUSIONS: This study demonstrates that an important goal in the effort to improve healthcare for patients with CMV-related disease is the establishment of traceable and commutable reference materials, including both calibrators and controls. .

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.269
Threshold uncertainty score0.720

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.391
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations72
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueClinical ChemistrySame topicCytomegalovirus and herpesvirus researchFrench-language works237,207