MétaCan
Menu
Back to cohort
Record W2030045795 · doi:10.1118/1.3469486

TH‐C‐BRB‐02: Determination of Average LET of Therapeutic Proton Beams Using A12O3:C Optically Stimulated Luminescence (OSL) Detectors

2010· article· en· W2030045795 on OpenAlexaff
G Sawakuchi, N Sahoo, P Gasparian, Louis Archambault, U Titt, E.G. Yukihara

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsHôtel-Dieu de Québec
Fundersnot available
KeywordsSobpDosimeterOptically stimulated luminescenceProtonCalibration curveIrradiationOpticsProton therapyDosimetryBeam (structure)CalibrationBragg peakMaterials sciencePhysicsPercentage depth dose curveLuminescenceRadiationNuclear medicineNuclear physicsChemistryIonization chamber

Abstract

fetched live from OpenAlex

Purpose: To measure the linear energy transfer (LET) of therapeutic proton beams using the optically stimulated luminescence (OSL) properties of commercial Al2O3:C dosimeters (OSLDs). Method and Materials: We irradiated Al2O3:C dosimeters at the M. D. Anderson Cancer Center passive scattering nozzles with unmodulated and spread‐out Bragg peak (SOBP) beams. The irradiations with unmodulated beams provided data to determine an LET calibration curve; and the irradiations with SOBP beams tested our LET calibration curve. The OSLDs were readout at Oklahoma State University using a Riso/ TL/OSL‐DA‐15 reader. We normalized our OSL decay curves to their initial intensities and defined the Γ factor as the area under the normalized OSL decay curve which characterized the shape of the OSL decay curve. A validated MCNPX model of the passive scattering beam nozzle was used to determine the average LET of the proton beams. To determine the LET calibration curve OSLDs were irradiated with various beam qualities and the Γ factor was obtained for each irradiation condition. To test the proposed technique we irradiated OSLDs in various depths of clinical SOBP fields. We analyzed the OSLDs and obtained the Γ factor for each irradiation condition and then we used the LET calibration curve to determine the average LET of the fields to which the detectors were irradiated. We calculated the average LET using MCNPX under the same irradiation conditions. Results: Average LET measurements and simulations agreed within 24% and 14% for 140 MeV and 250 MeV SOBP fields respectively. This was the first time that such agreement was obtained using any luminescence detectors (OSLDs and TLDs). Conclusion: The LET dependence of the OSL decay curve's shape from Al2O3:C dosimeters can be used to define an LET calibration curve which in turn can be used to measure average LET of therapeutic proton beams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.299
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207