MétaCan
Menu
Back to cohort
Record W2030173942 · doi:10.1007/s00167-014-2945-1

The sizing of hamstring grafts for anterior cruciate reconstruction: intra‐ and inter‐observer reliability

2014· article· en· W2030173942 on OpenAlexaff
Tim Dwyer, Daniel B. Whelan, Amir Khoshbin, David Wasserstein, Andrew P. Dold, Jaskarndip Chahal, Aaron Nauth, M. Lucas Murnaghan, Darrell Ogilvie‐Harris, John Theodoropoulos

Bibliographic record

VenueKnee Surgery Sports Traumatology Arthroscopy · 2014
Typearticle
Languageen
FieldMedicine
TopicKnee injuries and reconstruction techniques
Canadian institutionsToronto Western HospitalSt. Michael's HospitalWomen's College HospitalUniversity of TorontoMount Sinai Hospital
Fundersnot available
KeywordsHamstringAnterior cruciate ligament reconstructionMedicineSizingDrillCadaverOrthodonticsAnterior cruciate ligamentSurgeryReliability (semiconductor)Materials science

Abstract

fetched live from OpenAlex

PURPOSE: The objective of this study was to establish the intra- and inter-observer reliability of hamstring graft measurement using cylindrical sizing tubes. METHODS: Hamstring tendons (gracilis and semitendinosus) were harvested from ten cadavers by a single surgeon and whip stitched together to create ten 4-strand hamstring grafts. Ten sports medicine surgeons and fellows sized each graft independently using either hollow cylindrical sizers or block sizers in 0.5-mm increments—the sizing technique used was applied consistently to each graft. Surgeons moved sequentially from graft to graft and measured each hamstring graft twice. Surgeons were asked to state the measured proximal (femoral) and distal (tibial) diameter of each graft, as well as the diameter of the tibial and femoral tunnels that they would drill if performing an anterior cruciate ligament (ACL) reconstruction using that graft. Reliability was established using intra-class correlation coefficients. RESULTS: Overall, both the inter-observer and intra-observer agreement were >0.9, demonstrating excellent reliability. The inter-observer reliability for drill sizes was also excellent (>0.9). Excellent correlation was seen between cylindrical sizing, and drill sizes (>0.9). CONCLUSIONS: Sizing of hamstring grafts by multiple surgeons demonstrated excellent intra-observer and intra-observer reliability, potentially validating clinical studies exploring ACL reconstruction outcomes by hamstring graft diameter when standard techniques are used. LEVEL OF EVIDENCE: III.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.044
metaresearch head score (Gemma)0.081
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.044
Threshold uncertainty score0.230

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0440.081
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.257
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueKnee Surgery Sports Traumatology ArthroscopySame topicKnee injuries and reconstruction techniquesFrench-language works237,207