MétaCan
Menu
Back to cohort

Validity Study for the Cervical Range of Motion Device Used for Lateral Flexion in Patients With Neck Pain

2002· article· en· W2031959255 on OpenAlexaff
Michel Tousignant, Erica Duclos, Stéphane Laflèche, Any Mayer, Yannick Tousignant‐Laflamme, Lucie Brosseau, Joseph P. O’Sullivan

Bibliographic record

VenueSpine · 2002
Typearticle
Languageen
FieldMedicine
TopicMusculoskeletal pain and rehabilitation
Canadian institutionsObject Research Systems (Canada)Health and Social Services Centre University Institute of Geriatrics of SherbrookeOttawa HospitalCanadian Physiotherapy AssociationUniversity of Ottawa
Fundersnot available
KeywordsMedicineRange of motionNeck painConfidence intervalRadiographyCervical vertebraeOrthodonticsReliability (semiconductor)Cervical spineGold standard (test)PopulationPhysical therapySurgeryRadiologyInternal medicine

Abstract

fetched live from OpenAlex

STUDY DESIGN: A set of measurements was compared with an accepted gold standard using a methodologic design. OBJECTIVE: To estimate the criterion validity of the cervical range of motion device used for lateral flexion in patients with neck pain. SUMMARY OF BACKGROUND DATA: Reliability of the cervical range of motion device has been well established. At this writing, only validity for flexion and extension of the cervical spine has been investigated with this device. METHODS: The sample consisted of 24 volunteer subjects who had previously received physiotherapy for neck pain. In the radiograph department, subjects were stabilized on a chair. A first reading on the cervical range of motion device and a radiograph were taken in a neutral starting position. The subject then was asked to perform a maximal right lateral flexion, which was followed by a reading of the device and a second radiograph. The same procedures were followed for left lateral flexion. RESULTS: The cervical range of motion device demonstrated a very good linear relation with the radiograph measurements: left lateral flexion (r = 0.82,; 95% confidence interval, 0.62-0.92), right lateral flexion (r = 0.84; 95% confidence interval, 0.66-0.93). CONCLUSIONS: The cervical range of motion device showed very good validity for measurement of lateral flexion in this population of patients with neck pain. Because the reliability of the cervical range of motion device was established previously, the results of this study suggest that the device be used as an outcome measure for the cervical flexion, and for flexion and extension.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.012
Threshold uncertainty score0.163

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.294
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations96
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicMusculoskeletal pain and rehabilitationFrench-language works237,207