MétaCan
Menu
Back to cohort
Record W2033632666 · doi:10.1097/mnm.0b013e328332b32a

Quantification of regional myocardial blood flow in a canine model of stunned and infarcted myocardium: comparison of rubidium-82 positron emission tomography with microspheres

2009· article· en· W2033632666 on OpenAlexafffund
Katie S. Lekx, Robert A. deKemp, Robert Beanlands, Gerald Wisenberg, R. Glenn Wells, Robert Z. Stodilka, Mireille Lortie, Ran Klein, Pamela Zabel, Michael S. Kovacs, Jane Sykes, Frank S. Prato

Bibliographic record

VenueNuclear Medicine Communications · 2009
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of OttawaSt Joseph's Health CareLondon Health Sciences CentreLawson Health Research Institute
FundersCanadian Institutes of Health Research
KeywordsPerfusionMedicineBlood flowNuclear medicinePositron emission tomographyMicrosphereMyocardial stunningDobutamineStunningMyocardial infarctionInternal medicineCardiologyCoronary circulationCoronary occlusionHemodynamicsIschemia

Abstract

fetched live from OpenAlex

BACKGROUND: Myocardial viability and quantification of regional myocardial blood flow (MBF) are important for the diagnosis of heart disease. Positron emission tomography is the current gold standard for determining myocardial viability, but most positron-emitting perfusion tracers require an on-site cyclotron. Rubidium-82 ((82)Rb) is a myocardial perfusion tracer that is produced using an on-site generator. This study investigates (82)Rb-measured MBF in canine models of stunned and infarcted myocardium compared with selected measurements obtained concurrently using microspheres. METHODS: Myocardial stunning and infarction were created in canines by occluding the left anterior descending for 15 min and 2 h, respectively. Stunning was produced in all animals; six animals were reperfused after the 2 h occlusion, whereas the other six animals remained occluded permanently. Regional MBF was measured in each group during rest and dobutamine stress at acute and chronic (8 weeks postinsult) time points using dynamic (82)Rb perfusion imaging and radioactively labeled microspheres. RESULTS: Average resting MBF with microspheres and Rb was 0.68+/-0.02 versus 0.73+/-0.01 (P<0.001) in nonischemic tissue, and 0.53+/-0.03 versus 0.42+/-0.02 (P<0.001) in the region-at-risk tissue, respectively. Average MBF during stress with microspheres and Rb was 2.78+/-0.15 versus 3.53+/-0.16 (P<0.05) in the nonischemic tissue, and 1.90+/-0.20 versus 2.31+/-0.26 (P = NS) in the region-at-risk tissue, respectively. CONCLUSION: Despite the small significant differences, the dynamic (82)Rb measurements provide estimates of MBF in stunned and acutely and chronically infarcted tissue at rest and during hyperemia that correspond with clinical interpretation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.309
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueNuclear Medicine CommunicationsSame topicCardiac Imaging and DiagnosticsFrench-language works237,207