Occupational Noise Exposure during Endourologic Procedures

2008· article· en· W2033909530 on OpenAlexaffabout
Frédéric Soucy, Raymond Ko, John D. Denstedt, Hassan Razvi

Bibliographic record

VenueJournal of Endourology · 2008
Typearticle
Languageen
FieldMedicine
TopicKidney Stones and Urolithiasis Treatments
Canadian institutionsSt Joseph's Health CentreSt Joseph's Health CareUniversité Laval
Fundersnot available
KeywordsMedicineDecibelPercutaneous nephrolithotomySound level meterLithotripsyShock wave lithotripsyUreteroscopyPercutaneousSurgeryNoise levelHearing lossUreterAudiology

Abstract

fetched live from OpenAlex

INTRODUCTION: Long-term noise exposure in the workplace is a known cause of hearing loss. There has been limited study on the potential harm related to shock wave lithotripsy (SWL) or intracorporeal devices on patients and operating room personnel. PATIENTS AND METHODS: We used a digital sound meter to measure decibel levels in the operating room during several endourologic procedures. The decibel levels were recorded during SWL (Storz SLX-F2), percutaneous nephrolithotomy using single- and dual-probe ultrasonic lithotripters (Olympus LUS-2, CyberWand), and during ureteroscopy using the Versa Pulse Holmium:YAG laser. Findings were compared with the U.S. Department of Labor Occupational Health and Safety Administration and Canadian Centre for Occupational Health recommendations on permissible noise levels in the workplace. RESULTS: The background sound level in the operating room prior to endourologic procedures ranged between 58 and 60 dB. In the SWL control room, 5 m from the source, the mean sound level was 68 dB (range 64-75) during treatment. The mean corresponding decibel level recorded at the patient's head during SWL was 77 dB (range 73-83). Noises produced by intracorporeal lithotripters were recorded at the surgeon's head, 2 m from the source. Measurements of the CyberWand (dual-probe) device revealed a higher mean decibel reading of 93 dB (range 85-102). Noise levels recorded for the Olympus LUS-2 (single-probe) ultrasound and the holmium laser were 65 dB (62 -68) and 60 dB (58-62), respectively. CONCLUSION: Although we noted that patients and urologists maybe exposed to significant noise levels during endourologic procedures, the duration of exposure is short. This risk appears to be minimal, based on current occupational guidelines, for most operating personnel.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.051
Threshold uncertainty score0.452

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.284
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueJournal of EndourologySame topicKidney Stones and Urolithiasis TreatmentsFrench-language works237,207