MétaCan
Menu
Back to cohort

3D MR DSA: Effects of injection protocol and image masking

2000· article· en· W2034928043 on OpenAlexaff
Richard Frayne, Thomas M. Grist, J. Shannon Swan, Dana C. Peters, Frank R. Korosec, Charles A. Mistretta

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2000
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of Calgary
FundersNational Heart, Lung, and Blood Institute
KeywordsContrast (vision)SubtractionImage qualityDigital subtraction angiographyMasking (illustration)Volume (thermodynamics)Image subtractionNuclear medicineMagnetic resonance imagingMedicineContrast mediumRadiologyAngiographyImage (mathematics)Computer scienceMathematicsImage processingArtificial intelligencePhysics

Abstract

fetched live from OpenAlex

The purpose of this study was to investigate the effect on three-dimensional (3D) magnetic resonance digital subtraction angiography (MR DSA) images of various injection protocol parameters (ie, injection order, volume, and rate), as well as image masking. The pelves of 10 normal volunteers were scanned using seven different contrast agent volume/injection rate combinations. Subtraction of a precontrast mask image resulted in vascular image contrast improvements of between 4.0 and 7.7 times. Image quality and smaller vessel image contrast in the masked data decreased with increasing injection number. Data acquired with a high (0.150 mmol kg(-1)) volume yielded the highest quality images, although only small nonsignificant differences in image quality and large vessel conspicuity were found between images obtained using the high and medium (0.075 mmol kg(-1)) volumes. Images acquired with a low (0. 038 mmol kg(-1)) volume, while of lower image contrast, were judged to be of reasonable quality, especially when acquired as the first or second injection. Injection rate (1 ml s(-1), 2 ml s(-1), and 4 ml s(-1)) was not found to affect the images significantly, although selection of an injection rate that gave an injection duration of approximately 10 seconds tended to give better vascular image contrast. Based on these data, a series of escalating volumes for multi-injection examination is proposed. J. Magn. Reson. Imaging 2000;12:476-487.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.011
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.298
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207