A bench‐top megavoltage fan‐beam CT using ‐photodiode detectors. II. Image performance evaluation

2006· article· en· W2035043839 on OpenAlexafffund
T. T. Monajemi, Dongsheng Tu, B. G. Fallone, S Rathee

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Alberta
FundersCanadian Institutes of Health Research
KeywordsDetective quantum efficiencyPhotodiodeOpticsDetectorScintillatorScannerNuclear medicinePhysicsImage qualityCalibrationCone beam computed tomographyMedical imagingX-ray detectorMedicineRadiologyComputed tomographyComputer science

Abstract

fetched live from OpenAlex

Megavoltage computed tomography (MVCT) is a potential imaging tool for positioning and dose delivery verification during image guided radiotherapy. The problem with many MVCT detectors, however, is their low detective quantum efficiency (DQE) which leads to poor low contrast resolution (LCR) and high image noise. This makes separating the tumors from the soft tissue background difficult. This manuscript describes the imaging performance of our bench-top MVCT scanner that uses an 80-element detector array consisting of CdWO4-photodiode elements with a DQE of 19% in 6 MV and 26% in Co60 beams [T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, "Modelling scintillator-photodiodes as detectors for megavoltage CT," Med. Phys. 31, 1225-1234 (2004)] at zero frequency. The imaging experiments presented were carried out mainly in a Co60 teletherapy unit, while the beam hardening characteristics of the system were also presented for a 6 MV beam. During image evaluation, persistent ring artifacts, caused by air gaps at the ends of the eight-element detector blocks, were removed by using a calibration procedure. The measured contrast of a low contrast target with a 20 mm diameter was determined to be independent of dose, between 2.1 and 17 cGy. The measured LCR of a target with a nominal contrast of 2.8% was reduced from 2.3% to 1.2% when the contrast target diameter was reduced from 15 to 5 mm, using 17 cGy for imaging. The signal to noise ratio of this system is shown to be proportional to the square root of dose. Most importantly, a low contrast target with a diameter of 6 mm and a nominal contrast level of 1.5% is resolved with a radiation dose of 2.1 cGy in the Co60 beam. The spatial resolution in the Co60 beam is limited to one line pair per centimeter mainly due to the size of the Co60 source.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.680
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.292
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2006
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207