Pulmonary surfactant is altered during mechanical ventilation of isolated rat lung

2000· article· en· W2035319479 on OpenAlexaff
Ruud A. W. Veldhuizen, Lorraine N. Tremblay, Anand Govindarajan, Bianca A. W. M. van Rozendaal, Henk P. Haagsman, Arthur S. Slutsky

Bibliographic record

VenueCritical Care Medicine · 2000
Typearticle
Languageen
FieldMedicine
TopicNeonatal Respiratory Health Research
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicinePositive end-expiratory pressurePulmonary surfactantVentilation (architecture)Mechanical ventilationPulmonary complianceAnesthesiaLungTidal volumePeak inspiratory pressureLung volumesCompliance (psychology)Artificial ventilationRespiratory systemRespiratory diseaseInternal medicineChemistry

Abstract

fetched live from OpenAlex

OBJECTIVE: To test the hypothesis that the lung injury induced by certain mechanical ventilation strategies is associated with changes in the pulmonary surfactant system. DESIGN: Analysis of the pulmonary surfactant system from isolated rat lungs after one of four different ventilatory strategies. SETTING: A research laboratory at a university. SUBJECTS: A total of 45 Sprague-Dawley rats. INTERVENTIONS: Isolated lungs were randomized to either no ventilation (0-TIME) or to ventilation at 40 breaths/min in a humidified 37 degrees C chamber for either 30 mins or 120 mins with one of the following four strategies: a) control (CON, 7 mL/kg, 3 cm H2O positive end-expiratory pressure); b) medium volume, zero end-expiratory pressure (MVZP, 15 mL/kg, 0 cm H2O end-expiratory pressure); c) medium volume, high positive end-expiratory pressure (MVHP, 15 mL/kg, 9 cm H2O positive end-expiratory pressure); and d) high volume, zero end-expiratory pressure (HVZP, 40 mL/kg, 0 cm H2O end-expiratory pressure). MEASUREMENTS: Pressure-volume curves were determined before and after the ventilation period, after which the lungs were lavaged for surfactant analysis. MAIN RESULTS: Compared with 0-TIME, 30 mins of ventilation with the HVZP strategy or 120 mins of ventilation with CON and MVZP strategies caused a significant decrease in compliance. Groups showing a decreased compliance had significant increases in the amount of surfactant, surfactant large aggregates, and total lavage protein compared with 0-TIME. CONCLUSIONS: A short period of injurious mechanical ventilation can cause a decrease in lung compliance that is associated with a large influx of proteins into the alveolar space and with alterations of the pulmonary surfactant system. The changes of surfactant in these experiments are different from those seen in acute lung injury, indicating that they may represent an initial response to mechanical ventilation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.211
Threshold uncertainty score0.992

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0090.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.394
Teacher spread0.355 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations61
Published2000
Admission routes1
Has abstractyes

Explore more

Same venueCritical Care MedicineSame topicNeonatal Respiratory Health ResearchFrench-language works237,207