MétaCan
Menu
Back to cohort
Record W2036961878 · doi:10.1121/1.1564606

Modeling the frequency dependence (5–120 MHz) of ultrasound backscattering by red cell aggregates in shear flow at a normal hematocrit

2003· article· en· W2036961878 on OpenAlexaff
Isabelle Fontaine, Guy Cloutier

Bibliographic record

VenueThe Journal of the Acoustical Society of America · 2003
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversité de MontréalHôpital Notre-Dame
Fundersnot available
KeywordsUltrasoundMaterials scienceAnisotropyHematocritScatteringErythrocyte aggregationOpticsBlood flowNuclear magnetic resonanceAcousticsPhysicsMedicine

Abstract

fetched live from OpenAlex

The frequency dependence of the ultrasound signal backscattered by blood in shear flow was studied using a simulation model. The ultrasound backscattered signal was computed with a linear model that considers the characteristics of the ultrasound system and tissue acoustic properties. The tissue scattering properties were related to the position and shape of the red blood cells (RBCs). A 2D microrheological model simulated the RBC dynamics in a Couette shear flow system. This iterative model, described earlier [Biophys. J. 82, 1696-1710 (2002)], integrates the hydrodynamic effect of the flow, as well as adhesive and repulsive forces between RBCs. RBC aggregation was simulated at 40% hematocrit and shear rates of 0.05-2 s(-1). The RBC aggregate sizes ranged, on average, from 3.3 RBCs at 2 s(-1) to 33.5 cells at 0.05 s(-1). The ultrasound backscattered power was studied at frequencies between 5-120 MHz and insonification angles between 0-180 degrees. At frequencies below approximately 30 MHz, the ultrasound backscattered power increased as the shear rate was decreased and the size of the aggregates was raised. A totally different scattering behavior was noted above 30 MHz. Typical spectral slopes of the backscattered power (log-log scale) between 5-25 MHz equaled 3.8, whereas slopes down to 0.6 were measured at 0.05 s(-1), between 40-60 MHz. The ultrasound backscattered power was shown to be angle dependent at low frequencies (5-25 MHz). The anisotropy persisted at high frequencies (>25 MHz) for small aggregates (at 2 s(-1)). In conclusion, this study sheds some light on the blood backscattering behavior with an emphasis on the non-Rayleigh regime. Additional experimental studies may be necessary to validate the simulation results, and to fully understand the relation between the ultrasound backscattered power, level of RBC aggregation, shear rate, frequency, and insonification angle.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.753
Threshold uncertainty score0.374

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.229
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of the Acoustical Society of AmericaSame topicUltrasound Imaging and ElastographyFrench-language works237,207