MétaCan
Menu
Back to cohort
Record W2037235723 · doi:10.1108/01439911211227971

Kinematic calibration of a 3‐DOF planar parallel robot

2012· article· en· W2037235723 on OpenAlexaff
Ahmed Joubair, Mohamed Slamani, Ilian A. Bonev

Bibliographic record

VenueIndustrial Robot the international journal of robotics research and application · 2012
Typearticle
Languageen
FieldEngineering
TopicRobotic Mechanisms and Dynamics
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsWorkspaceCalibrationRobot calibrationRobotKinematicsLaser trackerPlanarCoordinate-measuring machineComputer scienceComputer visionPosition (finance)Frame (networking)Parallel manipulatorOrientation (vector space)Artificial intelligenceBase (topology)Robot kinematicsEngineeringMobile robotMechanical engineeringMathematicsOpticsGeometryPhysics

Abstract

fetched live from OpenAlex

Purpose The purpose of this paper is to describe a calibration method developed to improve the absolute accuracy of a novel three degrees‐of‐freedom planar parallel robot. The robot is designed for the precise alignment of semiconductor wafers and, even though its complete workspace is slightly larger, the accuracy improvements are performed within a target workspace, in which the positions are on a disc of 170 mm in diameter and the orientations are in the range ±17°. Design/methodology/approach The calibration method makes use of a single optimization model, based on the direct kinematic calibration approach, while the experimental data are collected from two sources. The first source is a measurement arm from FARO Technologies, and the second is a Mitutoyo coordinate measurement machine (CMM). The two sets of calibration results are compared. Findings Simulation confirmed that the model proposed is not sensitive to measurement noise. An experimental validation on the CMM shows that the absolute accuracy inside the target workspace was improved by reducing the maximum position and orientation errors from 1.432 mm and 0.107°, respectively, to 0.044 mm and 0.009°. Originality/value This paper presents a calibration method which makes it possible to accurately identify the actual robot's base frame (base frame calibration), at the same time as identifying and compensating for geometric errors, actuator offsets, and even screw lead errors. The proposed calibration method is applied on a novel planar robot, and its absolute accuracy was found to improve to 0.044 mm.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.942
Threshold uncertainty score0.325

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.088
GPT teacher head0.328
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueIndustrial Robot the international journal of robotics research and applicationSame topicRobotic Mechanisms and DynamicsFrench-language works237,207