MétaCan
Menu
Back to cohort
Record W2038079503 · doi:10.1177/0954411912468638

Hydromechanical stimulator for chondrocyte-seeded constructs in articular cartilage tissue engineering applications

2012· article· en· W2038079503 on OpenAlexaff
Homeyra Pourmohammadali, Naveen Chandrashekar, John B. Medley

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2012
Typearticle
Languageen
FieldMedicine
TopicOsteoarthritis Treatment and Mechanisms
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsBiomedical engineeringCompression (physics)Materials scienceGlycosaminoglycanCartilageStimulationTissue engineeringShear (geology)Shear forceComposite materialAnatomyMedicine

Abstract

fetched live from OpenAlex

Mechanical stimulation is a key technique used for controlling the mechanical properties of tissue engineered articular cartilage constructs proposed for defect repair. The present study introduces a new technical method and device for 'hydromechanical' stimulation of tissue engineered articular cartilage constructs. The stimulation consists of simultaneous cyclic compression, frictional shear from a sliding indenter contact and direct pressurized fluid perfusion. Each of these modes of mechanical loading has been shown by other research groups to effectively stimulate tissue engineered constructs. A device for applying these conditions was designed, developed and tested. Two sets (high and low perfusion flow rates) of three experiments were performed, each with two samples subjected to hydromechanical stimulation conditions (compression and friction forces along with perfusion). Two other samples from each set were subjected to just compression and dynamic frictional shear forces, and two more were used as controls (not stimulated). The average amount of glycosaminoglycan retained in the constructs after 3 weeks ranked from low to high as follows: controls, hydromechanical conditions with the low-flow rate, hydromechanical conditions with the high-flow rate and just compression plus dynamic frictional shear. Statistically significant differences were not detected. However, future studies would focus on glycosaminoglycan production in the superficial zone, measuring the glycosaminoglycan released to the nutrient media, and address altering the hydromechanical stimulation parameters using the results of the present study as guidance, in attempts to achieve statistically significant increases in glycosaminoglycan production compared with the controls.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.256
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicOsteoarthritis Treatment and MechanismsFrench-language works237,207