MétaCan
Menu
Back to cohort
Record W2038329527 · doi:10.1118/1.1998240

MO‐D‐I‐609‐04: In Vitro Stability of a Liposome‐Based Multimodal Contrast Agent: A CT and MR Imaging Study

2005· article· en· W2038329527 on OpenAlexaff
Jinzi Zheng, Christine Allen, David A. Jaffray

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldMaterials Science
TopicLanthanide and Transition Metal Complexes
Canadian institutionsPrincess Margaret Cancer CentreUniversity of TorontoOntario Institute for Cancer Research
Fundersnot available
KeywordsIohexolLiposomeMagnetic resonance imagingNuclear medicineChemistryImaging phantomGadoliniumBiomedical engineeringNuclear magnetic resonanceMedicineRadiology

Abstract

fetched live from OpenAlex

Purpose: To investigate the stability of a liposome‐based multimodal contrast agent for computed tomography (CT) and magnetic resonance (MR) imaging in the presence of various environmental conditions in vitro using both imaging and chemical analysis techniques. Method and Materials: Liposomes encapsulating iohexol and gadoteridol were dialyzed in an 8000 molecular weight cut‐off dialysis bag against 250‐fold excess of physiological buffer and fetal bovine serum (FBS) at 37°C. The liposome‐based contrast agent was also irradiated to clinically relevant single doses ranging from 0.5 Gy to 32 Gy delivered at a rate of 3.9 Gy/min (6MV, photon beam, medical linear accelerator) at 37°C in physiological buffer and FBS. The same samples were imaged in a purpose‐built multimodal phantom using CT (120 kV, 200 mA) and MR (1.5T, TR/TE = 450/9) before and after either dialysis or irradiation. The mean CT and MR signal differential was measured over circular regions of interest. Chemical detection of iohexol and gadoteridol concentrations was performed using high performance liquid chromatography and inductively coupled plasma atomic emission spectrometry respectively. Results: Partial release of the encapsulated agents occurred during dialysis due to differences in osmotic pressure and volume distribution (in the presence and absence of blood proteins). This small degree of agent leakage caused the MR signal to slightly increase and the CT signal to slightly decrease. In addition, the imaging properties of the system were found to remain unchanged when clinically relevant radiation doses were applied. Conclusion: The liposome‐based multimodal contrast agent remained substantially stable under osmotic pressure and distribution volume changes, in the presence of blood proteins and clinically relevant radiation doses. This investigation showed the feasibility of employing this system for blood pool CT and MR imaging over the course of a radiation treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.416

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.272
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicLanthanide and Transition Metal ComplexesFrench-language works237,207