MétaCan
Menu
Back to cohort
Record W2041982827 · doi:10.1021/ac001323g

Nanoliter Solvent Extraction Combined with Microspot MALDI TOF Mass Spectrometry for the Analysis of Hydrophobic Biomolecules

2001· article· en· W2041982827 on OpenAlexafffund
Bernd O. Keller, Liang Li

Bibliographic record

VenueAnalytical Chemistry · 2001
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Alberta
KeywordsChemistryAnalyteMass spectrometryChromatographyExtraction (chemistry)Matrix-assisted laser desorption/ionizationSample preparationDesorptionBiomoleculeSolventAnalytical Chemistry (journal)Matrix (chemical analysis)AdsorptionOrganic chemistry

Abstract

fetched live from OpenAlex

A nanoliter solvent extraction technique combined with microspot matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is presented. This method involves the use of a nanoliter droplet containing organic solvents at the tip of a small capillary for extraction. The droplet is formed inside a microliter aqueous sample containing the analyte of interest. After extraction, the droplet is deposited onto a MALDI target precoated with a thin matrix layer. Since the nanoliter droplet never touches the sample container wall, any possible extraction of contaminants adsorbed on the plastic or glassware is avoided. In addition, there is no need to concentrate the organic phase after the extraction, thus avoiding any possible loss during the concentration step. The nanoliter volume can be readily deposited onto a MALDI target, producing a high analyte concentration within a microspot. Combined with microspot MALDI, this technique allows for very sensitive analysis of the extracted analyte. The performance of this technique is illustrated in several applications involving the detection of hydrophobic peptides or phospholipids. It is shown that very hydrophobic analytes can be extracted from small-volume samples containing a large amount of salts and/or more hydrophilic analytes, which tend to give dominant signals in conventional MALDI experiments. Nanoliter extraction of analyte from samples containing less than 100 nM hydrophobic analyte and over 1 microM easily ionized hydrophilic species is demonstrated. Finally, using the analysis of the ionophore valinomycin as an example, it is demonstrated that the technique is a more reliable tool for probing metal-peptide complexes than regular MALDI sample preparations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.033
Threshold uncertainty score0.996

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.272
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2001
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207