MétaCan
Menu
Back to cohort
Record W2042815292 · doi:10.1118/1.4736802

Scanning rats on the high resolution research tomograph (HRRT): A comparison study with a dedicated micro‐PET

2012· article· en· W2042815292 on OpenAlexafffund
Stephan Blinder, Katherine Dinelle, Vesna Sossi

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of British ColumbiaUniversity of British Columbia Hospital
FundersNatural Sciences and Engineering Research Council of CanadaMichael Smith Health Research BC
KeywordsReproducibilityImaging phantomPositron emission tomographyImage resolutionNuclear medicinePoint spread functionNeuroimagingTomographyBiomedical engineeringMaterials scienceNuclear magnetic resonanceMedical physicsComputer sciencePhysicsMedicineArtificial intelligenceOpticsMathematics

Abstract

fetched live from OpenAlex

PURPOSE: The Siemens ECAT high resolution research tomograph (HRRT) is a dedicated human brain PET camera with a 6% absolute sensitivity and a (2.3 mm)(3) spatial resolution, improving to (1.8 mm)(3) when point spread function (PSF) modeling algorithms are used. These values are very close to those of dedicated small animal PET cameras such as the Siemens microPET FOCUS 120 (F120). The larger axial and transaxial field of view of the HRRT compared to the F120 allows, in principle, for simultaneous imaging of several rodents thus potentially reducing scanning costs and time. This study investigates the feasibility of using the HRRT for quantitative small animal brain studies. METHODS: We compare, in terms of magnitude, reproducibility, and asymmetry, the nondisplaceable tissue input binding potentials (BP(ND)) in the striata obtained from [(11)C]methylphenidate scans of the same rats imaged on both the F120 and the HRRT. The animal studies are complemented by a phantom study aimed at investigating noise properties relevant to the size of typical regions of interest used in rat brain image analysis. RESULTS: (i) The BP(ND) values obtained from HRRT data are lower than those obtained on the F120 by 38% when PSF modeling is not used, while they are 7% higher with PSF modeling. (ii) The within animal reproducibility on the HRRT is 18% without PSF modeling, worse than the 6% reproducibility on the F120, and is even further degraded to a value of 27% with the use of PSF modeling. (iii) The asymmetry between the left and right striatum in healthy rats worsens from 4.7% in the F120 images to 7.8% in the HRRT images reconstructed without PSF modeling, and is even worse with a value of 14.8% when PSF modeling is used. (iv) Overshooting artifacts and clumpiness in the noise structure of the HRRT images reconstructed with PSF modeling are clearly visible. CONCLUSIONS: The spatial resolution achieved on the HRRT without the use of resolution recovery techniques is not sufficient to allow for reliable quantitative small animal brain imaging. While PSF modeling in the reconstruction of the HRRT images in principle improves the resolution close to the level of the F120, it also introduces small scale nonuniformity artifacts and overshooting artifacts which preclude reliable quantitative small animal brain imaging on the HRRT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.423
Threshold uncertainty score0.660

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.101
GPT teacher head0.415
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207