MétaCan
Menu
← Back to cohort

Initial Stability of Two Dental Implant Systems: Influence of Buccolingual Width and Probe Orientation on Resonance Frequency Measurements

2009· article· en· W2043036275 on OpenAlexvenueno aff
Tolga Fikret Tözüm, Ilser Türkyilmaz, Bilge Turhan Bal

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2009
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsResonance frequency analysisImplant stability quotientImplantDental implantOrientation (vector space)Materials scienceSpiral (railway)Stability (learning theory)DentistryBiomedical engineeringMathematicsMedicineComputer scienceGeometrySurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Although many factors seem to have an impact on the resonance frequency (RF) values of implants, there is a lack of evidence about some other parameters, which may have an influence on implant stability. PURPOSE: The aims of the study were to determine whether initial stability of a dental implant differs when the buccolingual width of the bone changes, to determine whether different orientations affect the RF measurements in the RF device, and to investigate two dental implants with different morphologies with regard to their initial stability. MATERIALS AND METHODS: Two implant systems (Tidal Spiral Dental Implant Systems, Huntsville, AL, USA, and MIS Seven, MIS Implants Technologies Ltd., Shlomi, Israel) with diameters of 3.75 mm and 4.2 mm and with a length of 13 mm were used. Following the insertion of implants, buccolingual thinning of the models was performed in 2-mm increments ranging between 0 and 8 mm. RESULTS: A statistically significant decrease for implant stability quotient (ISQ) values was noticed for both diameters and both systems for all dimensional time points of the blocks (p < .05). The second system (more number of threads) resulted with higher ISQ values for both diameters than the first system (lower number of threads) (p < .001). The orientation of the probe influenced the measurements, where a standard orientation is advisable for the magnetic RF device. CONCLUSION: Different implant surface geometries seem to behave in different patterns in terms of initial stability. Dimensional changes in buccolingual direction seem to have an impact on the initial stability, where wider implants also presented higher ISQ values than narrow ones.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.169
GPT teacher head0.488
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→