MétaCan
Menu
Back to cohort
Record W2043201458 · doi:10.1115/1.3191729

An MRI-Compatible Needle Manipulator Concept Based on Elastically Averaged Dielectric Elastomer Actuators for Prostate Cancer Treatment: An Accuracy and MR-Compatibility Evaluation in Phantoms

2009· article· en· W2043201458 on OpenAlex
Jean‐Sébastien Plante, Kenjiro Tadakuma, Lauren M. Devita, Daniel F. Kacher, Joseph R. Roebuck, Simon DiMaio, Ferenc A. Jólesz, Steven Dubowsky

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Medical Devices · 2009
Typearticle
Languageen
FieldEngineering
TopicDielectric materials and actuators
Canadian institutionsUniversité de Sherbrooke
FundersNational Institutes of HealthMassachusetts Institute of TechnologyNational Aeronautics and Space Administration
KeywordsActuatorScannerCompatibility (geochemistry)Computer scienceMagnetic resonance imagingKinematicsBistabilityBiomedical engineeringMaterials scienceArtificial intelligenceEngineeringRadiologyMedicinePhysics

Abstract

fetched live from OpenAlex

A parallel manipulator concept using bistable polymer actuators has been developed to perform prostate cancer biopsy, and deliver therapy within the bore of a magnetic resonance imaging (MRI) scanner. The dielectric elastomer actuators (DEAs) used in this manipulator concept are promising for MRI-compatible robotics because they do not interfere with the high magnetic fields of MRI while having good mechanical performance and being low cost. In the past, these actuators have been plagued by robustness problems when used in a continuous manner. Recent studies show that reliability significantly improves when DEAs are used in a bistable manner, as proposed here. This paper investigates the potential of the proposed manipulator concept by evaluating the positioning accuracy and MRI compatibility of a laboratory prototype, developed for clinically relevant design criteria. An analytical model of the manipulator kinematics is presented. Analytical and experimental results validate that the proposed technology can provide an accurate needle placement required to perform prostate cancer treatments. The prototype’s MRI compatibility is validated in a 3 T clinical MRI scanner. The parallel manipulator concept using bistable polymer actuators is shown to be a viable approach to perform MRI-guided needle insertions for prostate cancer biopsy and therapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.943
Threshold uncertainty score0.662

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.314
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it