MétaCan
Menu
Back to cohort
Record W2043594346 · doi:10.1021/ac102265w

Improved Precision of iTRAQ and TMT Quantification by an Axial Extraction Field in an Orbitrap HCD Cell

2011· article· en· W2043594346 on OpenAlexaff
Peter Pichler, Thomas Köcher, Johann Holzmann, Thomas Möhring, Gustav Ammerer, Karl Mechtler

Bibliographic record

VenueAnalytical Chemistry · 2011
Typearticle
Languageen
FieldChemistry
TopicAdvanced Proteomics Techniques and Applications
Canadian institutionsThermo Fisher Scientific (Canada)
FundersChristian Doppler ForschungsgesellschaftAustrian Science Fund
KeywordsOrbitrapChemistryIsobaric labelingQuantitative proteomicsMass spectrometryIon trapAnalytical Chemistry (journal)Accuracy and precisionQuadrupole ion trapTandem mass spectrometryIsobaric processTandem mass tagIonChromatographyProteomicsProtein mass spectrometryStatistics

Abstract

fetched live from OpenAlex

Improving analytical precision is a major goal in quantitative differential proteomics as high precision ensures low numbers of outliers, a source of false positives with regard to quantification. In addition, higher precision increases statistical power, i.e., the probability to detect significant differences. With chemical labeling using isobaric tags for relative and absolute quantitation (iTRAQ) or tandem mass tag (TMT) reagents, quantification is based on the extraction of reporter ions from tandem mass spectrometry (MS/MS) spectra. We compared the performance of two versions of the LTQ Orbitrap higher energy collisional dissociation (HCD) cell with and without an axial electric field with regard to reporter ion quantification. The HCD cell with the axial electric field was designed to push fragment ions into the C-trap and this version is mounted in current Orbitrap XL ETD and Orbitrap Velos instruments. Our goal was to evaluate whether the purported improvement in ion transmission had a measurable impact on the precision of MS/MS based quantification using peptide labeling with isobaric tags. We show that the axial electric field led to an increased percentage of HCD spectra in which the complete set of reporter ions was detected and, even more important, to a reduction in overall variance, i.e., improved analytical precision of the acquired data. Notably, adequate precision of HCD-based quantification was maintained even for low precursor ion intensities of a complex biological sample. These findings may help researchers in their design of quantitative proteomics studies using isobaric tags and establish HCD-based quantification on the LTQ Orbitrap as a highly precise approach in quantitative proteomics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.525

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.307
Teacher spread0.281 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAdvanced Proteomics Techniques and ApplicationsFrench-language works237,207