MétaCan
Menu
Back to cohort
Record W2044773604 · doi:10.1121/1.1633559

Development of a new standard laboratory protocol for estimation of the field attenuation of hearing protection devices: Sample size necessary to provide acceptable reproducibility

2003· article· en· W2044773604 on OpenAlexaff
William J. Murphy, John R. Franks, Elliott H. Berger, Alberto Behar, John G. Casali, Christine Dixon-Ernst, Edward F. Krieg, Ben T. Mozo, Julia Doswell Royster, Larry H. Royster, Stephen D. Simon, Carol M. Stephenson

Bibliographic record

VenueThe Journal of the Acoustical Society of America · 2003
Typearticle
Languageen
FieldNeuroscience
TopicHearing Loss and Rehabilitation
Canadian institutionsThe Scarborough HospitalUniversity of Toronto
FundersNational Institute for Occupational Safety and Health
KeywordsHearing protectionAttenuationProtocol (science)ReproducibilityComputer scienceAbsolute threshold of hearingSample (material)AcousticsAudiologyStatisticsHearing lossMathematicsMedicinePhysics

Abstract

fetched live from OpenAlex

The mandate of ASA Working Group S12/WG11 has been to develop "laboratory and/or field procedure(s) that yield useful estimates of field performance" of hearing protection devices (HPDs). A real-ear attenuation at threshold procedure was selected, devised, tested for one earmuff and three earplugs via an interlaboratory study involving five laboratories and 147 subjects, and incorporated into a new standard that was approved in 1997 [Royster et al., "Development of a new standard laboratory protocol for estimating the field attenuation of hearing protection devices. Part I. Research of Working Group 11, Accredited Standards Committee S 12, Noise," J. Acoust. Soc. Am. 99, 1506-1526; ANSI, S12.6-1997, "American National Standard method for measuring real-ear attenuation of hearing protectors" (American National Standards Institute, New York, 1997)]. The subject-fit methodology of ANSI S12.6-1997 relies upon listeners who are audiometrically proficient, but inexperienced in the use of HPDs. Whenever a new method is adopted, it is important to know the effects of variability on the power of the measurements. In evaluation of protector noise reduction determined by experimenter-fit, informed-user-fit, and subject-fit methods, interlaboratory reproducibility was found to be best for the subject-fit method. Formulas were derived for determining the minimum detectable difference between attenuation measurements and for determining the number of subjects necessary to achieve a selected level of precision. For a precision of 6 dB, the study found that the minimum number of subjects was 4 for the Bilsom UF-1 earmuff, 10 for the E.A.R Classic earplug, 31 for the Willson EP100 earplug, and 22 for the PlasMed V-51R earplug.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.100
metaresearch head score (Gemma)0.071
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: Reproducibility · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.900
Threshold uncertainty score0.528

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.1000.071
Meta-epidemiology (narrow)0.0030.003
Meta-epidemiology (broad)0.0050.002
Bibliometrics0.0060.004
Science and technology studies0.0030.003
Scholarly communication0.0030.002
Open science0.0050.004
Research integrity0.0040.005
Insufficient payload (model declined to judge)0.0100.009

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.344
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designSimulation or modeling
DomainReproducibility
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of the Acoustical Society of AmericaSame topicHearing Loss and RehabilitationFrench-language works237,207