MétaCan
Menu
Back to cohort
Record W2044837816 · doi:10.1088/0952-4746/27/4/006

Improving the safety of a body composition analyser based on the PGNAA method

2007· article· en· W2044837816 on OpenAlexfundno aff
Seyyed Hashem Miri Hakimabad, R. Najafabadi, Alireza Vejdani-Noghreiyan, Hamed Panjeh

Bibliographic record

VenueJournal of Radiological Protection · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicNuclear Physics and Applications
Canadian institutionsnot available
FundersBC Cancer AgencyFasa University of Medical Sciences
KeywordsNeutronGamma rayAnalyserNeutron sourceNeutron activation analysisNeutron temperatureElectromagnetic shieldingNeutron fluxNuclear engineeringShieldRadiochemistryMaterials sciencePhysicsNuclear physicsOpticsChemistryGeology

Abstract

fetched live from OpenAlex

The 252Cf radioisotope and 241Am-Be are intense neutron emitters that are readily encapsulated in compact, portable and sealed sources. Some features such as high flux of neutron emission and reliable neutron spectrum of these sources make them suitable for the prompt gamma neutron activation analysis (PGNAA) method. The PGNAA method can be used in medicine for neutron radiography and body chemical composition analysis. 252Cf and 241Am-Be sources generate not only neutrons but also are intense gamma emitters. Furthermore, the sample in medical treatments is a human body, so it may be exposed to the bombardments of these gamma-rays. Moreover, accumulations of these high-rate gamma-rays in the detector volume cause simultaneous pulses that can be piled up and distort the spectra in the region of interest (ROI). In order to remove these disadvantages in a practical way without being concerned about losing the thermal neutron flux, a gamma-ray filter made of Pb must be employed. The paper suggests a relatively safe body chemical composition analyser (BCCA) machine that uses a spherical Pb shield, enclosing the neutron source. Gamma-ray shielding effects and the optimum radius of the spherical Pb shield have been investigated, using the MCNP-4C code, and compared with the unfiltered case, the bare source. Finally, experimental results demonstrate that an optimised gamma-ray shield for the neutron source in a BCCA can reduce effectively the risk of exposure to the 252Cf and 241Am-Be sources.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.279
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Radiological ProtectionSame topicNuclear Physics and ApplicationsFrench-language works237,207