MétaCan
Menu
Back to cohort

Relationship of the Implantable Cardioverter Defibrillator and Chronic Resynchronization Therapy: The Perfect Marriage?

2005· review· en· W2045738437 on OpenAlexaboutno aff
David S. Cannom, Morton M. Mower

Bibliographic record

VenueAnnals of Noninvasive Electrocardiology · 2005
Typereview
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineImplantable cardioverter-defibrillatorCardiac resynchronization therapyDefibrillationSudden cardiac deathHeart failureClinical trialInternal medicineSudden deathCardiologyIntensive care medicineEjection fraction

Abstract

fetched live from OpenAlex

Background: The two major modes of death in the patient with a reduced ejection fraction (EF) are death due to heart failure and death due to lethal arrhythmia, essentially the two sides of the same coin. Over the last 20 years, two therapies—cardiac resynchronization therapy (CRT) and the implantable cardioverter defibrillator (ICD)—have been developed and tested in clinical trials. They are now, in conjunction with appropriate medical therapy, the mainstays of therapy for these two commonly encountered clinical problems. Method and Results: Both of these therapies were conceived and patented by two Baltimore cardiologists, Michel Mirowski and Morton Mower ( Table I ). The path to everyday acceptance of both therapies was remarkably similar. The concept and early success of both devices was accomplished but the proof of concept depended on a series of carefully designed randomized clinical trials that showed that both the CRT and ICD devices saved lives in the low EF population, especially when used together. These trials overcame substantial skepticism on behalf of elements of the cardiology and electrophysiology establishment. Mirowski/Mower Legacy of Pivotal Therapies ICD CRT Concept 1970 Mid 1970s Patent 1971 1990 First implant 1981 1991 FDA/CMS approval 1984 2004 Pivotal trials MADIT I & II COMPANION SCD‐HeFT CARE‐HF AVID CIDS ICD = implantable cardioverter defibrillator; MADIT = Multicenter Automatic Defibrillator Implantation Trial; COMPANION = Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure; SCD‐HeFT = Sudden Cardiac Death in Heart Failure Trial; AVID = Antiarrhythmics versus Implantable Defibrillator; CIDS = Canadian Implantable Defibrillator Study. Conclusion: We are now at a crossroads in the further extension of either therapy. The majority of the indications for either device alone or in combination are established. In the next few years, assuming the continued commitment on the part of regulatory agencies to fully embrace evidence‐based medicine, we will see indications extended but only by the careful clinical trials that became the bedrock of their initial acceptance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.038
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.011
Threshold uncertainty score0.058

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.038
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0010.007
Scholarly communication0.0040.009
Open science0.0010.003
Research integrity0.0030.009
Insufficient payload (model declined to judge)0.0100.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.091
GPT teacher head0.365
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Noninvasive ElectrocardiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207