MétaCan
Menu
Back to cohort
Record W2047656744 · doi:10.1115/1.4005166

Dynamic Response of Intraocular Pressure and Biomechanical Effects of the Eye Considering Fluid-Structure Interaction

2011· article· en· W2047656744 on OpenAlexafffund
Samira Salimi, S. Simon Park, Theodor Freiheit

Bibliographic record

VenueJournal of Biomechanical Engineering · 2011
Typearticle
Languageen
FieldMedicine
TopicCorneal surgery and disorders
Canadian institutionsUniversity of Calgary
FundersMinistry of Advanced Education, Government of Alberta
KeywordsIntraocular pressureVibrationShell (structure)Fluid–structure interactionHuman eyeNatural frequencyFinite element methodFluid dynamicsMechanicsMaterials sciencePhysicsOpticsStructural engineeringAcousticsEngineeringOphthalmologyMedicine

Abstract

fetched live from OpenAlex

The vibration characteristics of shell structures such as eyes have been shown to vary with intraocular pressure (IOP). Therefore, vibration characteristics of the eye have the potential to provide improved correlation to IOP over traditional IOP measurements. As background to examine an improved IOP correlation, this paper develops a finite element model of an eye subject to vibration. The eye is modeled as a shell structure filled with inviscid pressurized fluid in which there is no mean flow. This model solves a problem of a fluid with coupled structural interactions of a generally spherically shaped shell system. The model is verified by comparing its vibrational characteristics with an experimental modal analysis of an elastic spherical shell filled with water. The structural dynamic effects due to change in pressure of the fluid are examined. It is shown that the frequency response of this fluid-solid coupled system has a clear increase in natural frequency as the fluid pressure rises. The fluid and structure interaction is important for accurate prediction of system dynamics. This model is then extended to improve its accuracy in modeling the eye by including the effect of the lens to study corneal vibration. The effect of biomechanical parameters such as the thicknesses of different parts of the eye and eye dimensions in altering measured natural frequencies is investigated and compared to the influence of biomechanical parameters in Goldmann applanation tonometry models. The dynamic response of the eye is found to be less sensitive to biomechanical parameters than the applanation tonometry model.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.019
Threshold uncertainty score0.359

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.223
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicCorneal surgery and disordersFrench-language works237,207