Co-Oximetry Interference by Hemoglobin-Based Blood Substitutes
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
UNLABELLED: The blood substitutes now being developed from molecularly modified hemoglobin interfere with a wide variety of clinical analyzers, but their effects on cooximeters are unknown. Therefore, we investigated the effects of five hemoglobin-based blood substitutes on the measurements of eight different oximeters and cooximeters: the AVL Omni 6, the AVOXimeters 1000 and 4000, the Ciba Corning (now Bayer) CC270 CO-Oximeter, the Instrumentation Laboratory Synthesis 35, the IL482 and IL682 CO-Oximeters, and the Radiometer OSM3 Hemoximeter. The five blood substitutes in this study were obtained from Apex Bioscience (Research Triangle Park, NC), Baxter Healthcare Corp. (Deerfield, IL), Biopure Corp. (Cambridge, MA), Hemoglobin Therapeutics, and Hemosol, Inc. (Etobicoke, Ontario, Canada). A cooximeter control was used to compare the eight different instruments' measurements on unaltered human hemoglobin. The instruments yielded measurements of total hemoglobin concentration in undiluted blood substitutes that were generally not more variable than those on the control material. By contrast, when compared with readings on controls, the test instruments yielded measurements of the fractional concentrations of oxy-, deoxy-, carboxy-, and methemoglobin that showed greater instrument-to-instrument disparities and larger standard deviations about the all-instrument means. In some cases, the interference was even more obvious: five of six cooximeters gave negative carboxyhemoglobin readings on one particular product. Our findings indicate that the instruments will give less accurate but clinically useful measurements in the presence of these hemoglobin-based blood substitutes. IMPLICATIONS: We investigated the effects of five hemoglobin-based blood substitutes on the measurements of eight different cooximeters. Some blood substitutes caused obvious interference, such as negative carboxyhemoglobin readings; however, the findings indicate that cooximeters will generally give less accurate but clinically useful measurements in the presence of the hemoglobin-based blood substitutes that were tested.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it