MétaCan
Menu
Back to cohort
Record W2048735628 · doi:10.1109/iembs.2011.6091425

Force relaxation and sprinback of novel elastic orthopedic cables

2011· article· en· W2048735628 on OpenAlexaff
Fanny Canet, Yannick Baril, Vladimir Braïlovski, Yvan Petit, Guillaume Bissonnette, Gilles Laflamme

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicBone fractures and treatments
Canadian institutionsUniversité de MontréalÉcole de Technologie SupérieureHôpital du Sacré-Cœur de Montréal
Fundersnot available
KeywordsMaterials scienceElongationComposite materialTitaniumStiffnessNickelCobaltMetallurgyUltimate tensile strength

Abstract

fetched live from OpenAlex

UNLABELLED: Cerclage cables have proven to be very useful in the orthopedic field for bones stabilization and plate fixation but the initial enthusiasm for metallic cables has declined with their high complication rates. Metal materials provide limited elastic deformation compromising their ability to maintain compression. This study compares the mechanical properties of new elastic cables with cobalt-chrome and stainless-steel cables. METHODS: Stainless-steel, cobalt-chrome, nylon and nickel-titanium cables were first loaded up to 356 N, then elongation was maintained for 12 hours, next unloaded and finally reloaded to failure. Initial elongation (%), Relative force relaxation (% loss of initial load after a 12h), elastic springback (%) and force to failure (N) were extracted from force-elongation curves. FINDINGS: Initial elongation was the highest for nylon cables (9%), followed by the nickel-titanium (4%) and both metallic cables (0.3%). During 12 hours, no relaxation was observed for the nickel-titanium and the cobalt-chrome cables, whereas 28 and 45% of the tension was lost respectively for the stainless-steel and the nylon cables. The elastic springback of the nickel-titanium and nylon cables (4.4 and 4.7% respectively) was 20 times higher than that of the stainless-steel and cobalt-chrome cables (0.12 and 0.16% respectively). The force to failure of the stainless steel and cobalt-chrome cables was twice that of the nickel-titanium cables. INTERPRETATION: Multi-braided stainless-steel and cobalt-chrome cables have a high-stiffness with limited ability to tolerate displacement, leading to early cable loosening. Novel low-stiffness cables made of nylon or nickel-titanium offer significant elastic springback improving binding stability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.257
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2011
Admission routes1
Has abstractyes

Explore more

Same topicBone fractures and treatmentsFrench-language works237,207