MétaCan
Menu
Back to cohort
Record W2048945864 · doi:10.1097/bot.0b013e318190ea7d

Biomechanical Evaluation of Extramedullary Versus Intramedullary Fixation for Reverse Obliquity Intertrochanteric Fractures

2008· article· en· W2048945864 on OpenAlexaff
Paul R.T. Kuzyk, Joel Lobo, Daniel B. Whelan, Rad Zdero, Michael D. McKee, Emil H. Schemitsch

Bibliographic record

VenueJournal of Orthopaedic Trauma · 2008
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsSt. Michael's HospitalUniversity of Toronto
Fundersnot available
KeywordsMedicineIntramedullary rodDynamic hip screwFemurFixation (population genetics)OrthodonticsBiomechanicsGreater trochanterStiffnessDisplacement (psychology)SurgeryAnatomyMaterials science

Abstract

fetched live from OpenAlex

OBJECTIVES: This study evaluated the 135-degree hip screw, 95-degree hip screw, and intramedullary hip screw (IMHS) for fixation of reverse obliquity intertrochanteric fractures. METHODS: Twelve matched pairs of human femora (mean age 64 years) were obtained. Osteotomies were created in left femurs at a 33-degree angle, running inferolaterally from the lesser trochanter to mimic reverse obliquity intertrochanteric fractures. Right femora acted as controls. Three groups of left femora (n = 4 per group) had a 135-degree hip screw, 95-degree hip screw, or IMHS inserted. Strain gages were placed distal to the fracture site to monitor fragment strain. A linearly variable differential transformer measured lateral displacement of the proximal femur. An Instron tester applied vertical loads to the femoral head. Outcome measures of stiffness, strain, and lateral displacement were determined at 25-degree adduction, 25-degree abduction, 25-degree flexion, and 90-degree flexion. A 2-cm bone gap was then created at the fracture site to simulate comminution and the mechanical tests repeated. Failure load was assessed in 25-degree adduction with a bone gap. RESULTS: There was no difference in normalized stiffness between constructs before creation of a gap. After gap creation, stiffness of all constructs was reduced (P = 0.03), and there was a significant difference in adduction (135-degree hip screw, 46.6% +/- 3%; 95-degree hip screw, 22.9% +/- 2%; and IMHS, 53.7% +/- 7.8%) (P < 0.05). Similar results were noted for abduction and flexion. There was no significant difference in lateral displacement between constructs before (P = 0.92) or after (P = 0.26) gap creation. Failure load was significantly different (135-degree hip screw, 1222 +/- 560 N; 95-degree hip screw, 2566 +/- 283 N; and IMHS, 4644 +/- 518 N) (P = 0.02). CONCLUSIONS: With bone contact, there were no statistically significant differences in the stiffness between the constructs. With a gap, however, the IMHS bone implant construct was significantly stiffer and had a greater load to failure than the 135-degree and 95-degree constructs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.780
Threshold uncertainty score0.587

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.364
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations72
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic TraumaSame topicHip and Femur FracturesFrench-language works237,207