Response: Hemolysis is a primary and physiologically relevant ATP release mechanism in human erythrocytes
Bibliographic record
Abstract
We appreciate the willingness of Kirby and colleagues to discuss methodological concerns in red blood cell (RBC) adenosine triphosphate (ATP) release studies. In our investigations, before moving to mechanism-probing experiments, we spent most of the time evaluating the different methods that have been used in the field to assess RBC ATP release and the contribution of hemolysis to that release. Although we began with the hypothesis that regulated ATP release mechanisms do operate in RBCs, after extensively verifying each experimental approach, we came to the conclusion expressed in the title: ie, that “Hemolysis is a primary ATP release mechanism in human erythrocytes.”1 In the course of the study, while attempting to reproduce previously published findings, we identified a number of methodological pitfalls (the major ones are discussed in the supplemental Methods available on Blood Web site), which likely precluded a proper evaluation of ATP release and also the contribution of hemolysis in the earlier studies2-10 cited by Kirby et al. We agree that “liberation of ATP secondary to hemolysis is not mutually exclusive of regulated export.”11 Our point is that without the controls described in our paper, a confounding effect of hemolysis cannot be excluded. We determined that the most reliable and direct evaluation of a hemolysis contribution to RBC ATP release requires the following. (1) The use of RBC supernatants for extracellular ATP (ATPec) evaluation rather than RBC suspensions is necessary. We verified that centrifugation (500g, 10 minutes, 4°C), even when repeated 5 times, does not elevate ATPec above the low basal level seen after the first or second centrifugation. (2) The measurement of free hemoglobin (Hb) in an aliquot of the same supernatant used for ATPec determination is necessary. To the best of our knowledge, such paired measurements have been performed only for plasma ATP-Hb determinations by Gorman et al12 and Kirby et al2 or toxin-induced ATP release.13 When ATPec-Hb values of all samples were plotted to evaluate the correlation between these variables, they showed a linear relationship and exactly matched those obtained with freshly prepared RBC lysates (see Figure 1D in Sikora et al1). Any “upward” deflection in the linear ATP-Hb relationship would indicate a contribution of nonlytic ATP release. With these restrictions, we found that ATP and Hb release were tightly correlated for all stimuli tested and exactly matched expectations based on the number of lysed cells and independently determined intracellular ATP concentration. Our conclusions were fully confirmed by directly visualizing single-cell ATP release and cell lysis using luminescence ATP imaging and simultaneous infrared cell imaging, respectively. We encourage other investigators to use these criteria and to examine the correlation between ATP and Hb release in individual experiments, so that conclusions can be made concerning regulated, hemolysis-independent mechanisms.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.002 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".