MétaCan
Menu
Back to cohort
Record W2052009203 · doi:10.1002/rcm.2769

Solid‐phase microextraction method for carbon isotopic analysis of volatile carboxylic acids in human plasma by gas chromatography/combustion/isotope ratio mass spectrometry

2006· article· en· W2052009203 on OpenAlexaff
Véronique Ferchaud‐Roucher, Corinne Albert, Martine Champ, Michel Krempf

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2006
Typearticle
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsHotel Dieu Hospital
FundersEuropean Commission
KeywordsChemistryChromatographySolid-phase microextractionMass spectrometryRepeatabilityIsotope-ratio mass spectrometryGas chromatographyGas chromatography–mass spectrometryExtraction (chemistry)Ethyl acetateAnalytical Chemistry (journal)

Abstract

fetched live from OpenAlex

A new analytical method is described for the determination of the physiological concentration and low-level enrichment of (13)C-short-chain volatile organic acids (SCVAs) (e.g. (13)C-acetate and (13)C-butyrate) in human plasma. This two-step method involves solid-phase microextraction (SPME) coupled to gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) without any organic solvents or derivatizing agents. Two SCVA extraction methods were compared using a carboxen/polydimethylsiloxane fiber: headspace sampling (HS) and liquid sampling (LS) SPME. The influences of extraction temperature and time were tested to optimize the adsorption of SCVAs onto the fiber. The comparison of the peak area responses of the acids in the two adsorption methods showed better sensitivity in the human physiological concentration range in the LS mode than in the HS mode. The accuracy of isotopic enrichment measurement was determined using plasma spiked with (13)C-acetate and (13)C-butyrate solution from 0 to 1 mol percent excess (MPE). The linearity and repeatability (RSD < 5%) were measured in LS mode. Plasma SCVA concentrations were also determined relative to 3-methylvalerate (internal standard). Linearity and repeatability were observed from 0 to 400 microM for acetate, from 0 to 20 microM for propionate, and from 0 to 10 microM for butyrate. This method was also used to determine plasma acetate production obtained from lactulose (an undigestible disaccharide) fermentation in one healthy volunteer over 3 h. The acetate concentration increased twofold, 2 h after oral lactulose intake. These results are in agreement with the data obtained by GC/MS in healthy volunteers and obese adults following a lactulose intake by using higher amounts of labelled tracers.SPME coupled with GC/C/IRMS can be used to analyze (13)C-SCVAs at low enrichment (<0.5 MPE) within the physiological concentration measured in human plasma.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.208
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0030.007
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.313
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207