MétaCan
Menu
Back to cohort
Record W2052447605 · doi:10.1002/jmri.21841

High‐field MRSI of the prostate using a transmit/receive endorectal coil and gradient modulated adiabatic localization

2009· article· en· W2052447605 on OpenAlexafffund
Jamie Near, Cesare Romagnoli, Andrew T. Curtis, L. Martyn Klassen, Jonathan I. Izawa, Joseph L. Chin, Robert Bartha

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2009
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsLondon Health Sciences CentreRobarts Clinical TrialsWestern University
FundersCanadian Institutes of Health Research
KeywordsElectromagnetic coilSpecific absorption rateImaging phantomVoxelAdiabatic processMaterials scienceFinite-difference time-domain methodNuclear magnetic resonanceProstateOpticsPhysicsComputer scienceRadiologyTelecommunicationsMedicineCancer

Abstract

fetched live from OpenAlex

PURPOSE: To demonstrate in vivo magnetic resonance spectroscopic imaging (MRSI) of the human prostate at 4.0T using a transmit/receive endorectal coil and a pulse sequence designed specifically for this application. MATERIALS AND METHODS: A solid, reusable endorectal probe was designed for both radiofrequency transmission and reception. Finite difference time domain (FDTD) simulations were performed to characterize the coil's electric field distribution, and temperature measurements were performed in a beef tissue phantom to determine the coil's safe operating limit. The localization by selective adiabatic refocusing (LASER) pulse sequence was implemented using six gradient modulated offset independent adiabatic (GOIA) pulses for very sharp, B(1)-insensitive voxel localization. RESULTS: Based on the simulations and temperature measurements, the coil's safe operating limit was conservatively estimated to be 1.0W for 15 minutes. The transition width of the GOIA pulse selection profiles was only 6% of the bandwidth, compared with 22% for a specific absorption rate (SAR)-matched conventional adiabatic pulse. Using the coil and pulse sequence described here, MRSI data were successfully acquired from a patient with biopsy-proven prostate cancer, with a nominal voxel size of 0.34 cc in a scan time of 15 minutes. CONCLUSION: This work demonstrates the safe and effective use of a transmit/receive endorectal coil for in vivo MRSI of the prostate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.257
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207