MétaCan
Menu
Back to cohort
Record W2053790085 · doi:10.1118/1.4894976

Sci—Thur PM: Imaging — 03: A novel Čerenkov detector based on air‐spaced light guiding taper for megavoltage x‐ray imaging

2014· article· en· W2053790085 on OpenAlexaff
A. Teymurazyan, J. A. Rowlands, Geordi Pang

Bibliographic record

VenueMedical Physics · 2014
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Optical Sensing Technologies
Canadian institutionsPrincess Margaret Cancer CentreHealth Sciences CentreThunder Bay Regional Research InstituteToronto Metropolitan UniversityUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsOpticsPhysicsLinear particle acceleratorDetectorPhotonCherenkov radiationCladding (metalworking)X-ray detectorQuantum efficiencyOptical fiberRadiationBeam (structure)OptoelectronicsMaterials science

Abstract

fetched live from OpenAlex

Electronic Portal Imaging Devices (EPIDs) have been used in radiation therapy and are still needed on linear accelerators (Linacs) equipped with kilovoltage cone beam CT (kV‐CBCT) or MRI systems. Recently a new concept of a high quantum efficiency (QE) Čerenkov Portal Imaging Device (CPID) for MV x‐ray imaging in radiation therapy was introduced. It relies on Čerenkov effect for x‐ray detection. The proposed design consisted of a matrix of optical fibres aligned with the incident x‐rays and coupled to an active matrix flat panel imager (AMFPI) for image readout. A weakness of such design is that too few Čerenkov light photons reach the AMFPI for each incident x‐ray and an AMFPI with an avalanche gain is required. In this work we propose to replace the optical fibers in the CPID with light guides without a cladding layer that are suspended in air. The air between the light guides takes on the role of the cladding layer found in a regular optical fiber. Since air has a significantly lower refractive index, a much superior light collection efficiency is achieved. Our Monte Carlo studies have shown that the modified new CPID has a QE more than an order of magnitude greater than that of current clinical systems and yet a spatial resolution similar to that of current flat‐panel based EPIDs. Furthermore it has been demonstrated that the new CPID does not require an avalanche gain in the AMFPI and is quantum noise limited at dose levels corresponding to a single Linac pulse.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.965
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.255
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Optical Sensing TechnologiesFrench-language works237,207