MétaCan
Menu
Back to cohort
Record W2057688241 · doi:10.1088/0031-9155/46/8/307

Comparison of dosimetric standards of Canada and France for photons at<sup>60</sup>Co and higher energies

2001· article· en· W2057688241 on OpenAlexaffabout
K R Shortt, C. K. Ross, Jan Seuntjens, F Delaunay, A. Ostrowsky, P. Gross

Bibliographic record

VenuePhysics in Medicine and Biology · 2001
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNational Research Council Canada
FundersInternational Atomic Energy Agency
KeywordsPhotonPhysicsDosimetryNuclear physicsNuclear medicineMedical physicsOpticsMedicine

Abstract

fetched live from OpenAlex

We report the results of a comparison of the dosimetric standards of Canada and France for photon beams at 60Co and a few higher energies. The present primary standard of absorbed dose to water for NRC, Canada is based on measurements made with a sealed water calorimeter. The corresponding standard of the LNHB, France is based on measurements made with a graphite calorimeter at 60Co energy and transferred to absorbed dose to water for 60Co and higher-energy photon beams using both ion chambers and Fricke dosemeters as transfer instruments. To make this comparison, we used three graphite-walled NE2571 Farmer chambers. The absorbed dose to water determined by the LNHB was greater than that determined by NRC by 0.20% at 60Co energy. This difference is not significant given the uncertainties on the standards. In order to do the comparison for higher-energy photons, we interpolated the NRC data set at the beam qualities used at the LNHB. When %dd(10)x is used as the method of specifying beam quality, the determination of absorbed dose to water by the LNHB is about 0.2% greater than that determined by NRC and consistent with the results at 60Co. However, when using TPR20,10 as the beam quality specifier, the LNHB determination is greater than the NRC's determination by 0.8% and 1.2% at 12 and 20 MV respectively. This discrepancy, which systematically increases with increasing energy, eventually exceeds the uncertainties in the ratio of the standards, estimated to be 0.7%. This underscores the importance of selecting the method of specifying beam quality, either %dd(10)x or TPR20,10, at least for the 'soft' beams used by NRC in this comparison. In the case of the air kerma standards, which were also compared at 60Co energy, the LNHB determination was greater than NRC's by 0.14%, which is not significant given the uncertainties on the standards.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.572
Threshold uncertainty score0.861

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0040.004
Science and technology studies0.0010.001
Scholarly communication0.0020.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.062
GPT teacher head0.399
Teacher spread0.337 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2001
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207