MétaCan
Menu
← Back to cohort
Record W2057953646 · doi:10.1118/1.2761754

TH-E-M100J-01: A Novel Deformable Lung Phantom for 4D Radiotherapy Verification

2007· article· en· W2057953646 on OpenAlexaff
M Margeanu, Gabriela Stroian, Emily Heath, Jan Seuntjens

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill UniversityMontreal General Hospital
Fundersnot available
KeywordsImaging phantomDiaphragm (acoustics)Materials scienceBiomedical engineeringPiston (optics)Nuclear medicineBalloonCylinderReproducibilityPhysicsMedicineOpticsAcousticsGeometryMathematicsSurgery

Abstract

fetched live from OpenAlex

Purpose: To develop a reproducible, tissue equivalent, deformable lung phantom for verification of 4D-CT scanning procedures, deformable image registration (DIR) and 4D dose calculation in moving/deformable anatomies. Methods and Materials: The phantom consists of a Lucite cylinder filled with water containing a latex balloon filled with dampened natural sponges. The balloon is attached to a piston that mimics the human diaphragm. Nylon wires and Lucite beads, emulating vascular and bronchial bifurcations, were glued at various locations, uniformly, throughout the sponges. The phantom is capable of simulating programmed irregular breathing patterns with varying periods and amplitudes. A deformable, tissue equivalent tumour holding radiochromic film was embedded in the sponge. Eight 3D-CT datasets (0.7×0.7×1.25 mm) of the phantom in eight static positions of the piston were acquired. 3D trajectories of 12 anatomical point landmarks as well as the tumour center-of-mass were studied. Results: Reproducible lung deformation is achieved by piston-provoked pressure changes in water surrounding the deforming balloon. The resulting mean density for the artificial lung was 0.243 g/cm3 comparable to 0.252 g/cm3 for a real lung. A truly 3D, non-isotropic deformation of the balloon similar to a real lung has been obtained. The SI displacement of the landmarks varies between 94% and 3% of the diaphragm excursion for positions closer and farther away from the diaphragm, respectively. Reproducibility in the deformed phantom, established by seven repeat scans at the same phantom compression state, was within image resolution. The accuracy of DIR of the extreme phases was 0.7(±0.7) mm. Conclusions: Our novel phantom is tissue-equivalent, deformable, and can reproducibly emulate 3D non-isotropic lung deformations. The presence of vascular and bronchial bifurcations allows verification of DIR of 4D-CT images of the phantom. Registered phases of the phantom can be used in 4D dose calculations that can be validated by comparison with dose measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.315
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→