MétaCan
Menu
Back to cohort
Record W2058126074 · doi:10.1118/1.2403968

Calculation of lateral buildup ratio using Monte Carlo simulation for electron radiotherapy

2006· article· en· W2058126074 on OpenAlexaff
James C. L. Chow

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer CentreUniversity Health Network
Fundersnot available
KeywordsMonte Carlo methodElectron scatteringDosimetryElectronDosimeterComputational physicsPhysicsLinear particle acceleratorScatteringRadiationOpticsComputer scienceNuclear medicineBeam (structure)Nuclear physicsMathematics

Abstract

fetched live from OpenAlex

Monte Carlo simulation was used to calculate the lateral buildup ratio (LBR) used in estimating the percentage depth dose (PDD) and dose per monitor unit for an irregular shaped cutout field in electron radiotherapy. Monte Carlo code BEAMnrc/EGSnrc was used to build a simulation model for a Varian 21 EX linear accelerator producing clinical electron beams with energies of 4, 6, 9, 12, and 16 MeV. The model is optimized by adjusting the incident electron energy within the Monte Carlo simulation so that the calculated PDD curves agree with the measurement within +/-2%. The LBR is calculated from the PDD curves for different diameters of circular cutouts. Although Monte Carlo simulation requires a longer time to create a LBR database compared to measurement using scanning water tank and dosimeter, the simulation models for different electron energies, applicators, and cutouts are very similar. As the calculations can be carried out in a batch mode automatically run by a computer, human efforts in carrying out measurements in the treatment room and fabricating the circular cutouts in the mold room are greatly saved. Moreover, the simulation avoids human error in the experimental setup and can better handle the electron scattering affecting accuracy in the measurement. Using Monte Carlo simulation to calculate the LBR is proved to be useful in the commissioning of the electron beams for electron radiotherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.702
Threshold uncertainty score0.498

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.316
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207