MétaCan
Menu
Back to cohort
Record W2058470355 · doi:10.1167/iovs.03-0239

Topographical Thickness of the Epithelium and Total Cornea after Overnight Wear of Reverse-Geometry Rigid Contact Lenses for Myopia Reduction

2003· article· en· W2058470355 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueInvestigative Ophthalmology & Visual Science · 2003
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
FundersU.S. Food and Drug Administration
KeywordsCorneaOphthalmologyContact lensAutorefractorLens (geology)Effects of long-term contact lens wear on the corneaRefractive errorCorneal epitheliumMeridian (astronomy)Optical coherence tomographyMedicineMaterials scienceOpticsAnatomyEye diseasePhysics

Abstract

fetched live from OpenAlex

PURPOSE: To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses. METHODS: Reverse geometry design CRT (Dk=100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 +/- 2.7 years) and the other eye was fitted with an alignment tricurve rigid lens of the same material (control). Epithelial and total corneal thickness was measured at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after overnight wear. Refractive error was measured with an autorefractor. These measurements were repeated 20 and 60 minutes and 3, 6, and 12 hours after lens removal. RESULTS: After one night of lens wear, myopia decreased in the test eye by 1.18 +/- 0.81 D, which was significantly different from baseline (P<0.001). No significant change was found in the control eye. Twelve hours after removal, two thirds of the myopic reduction was still present. Different topographical swelling patterns were induced by the two lens designs, with greatest swelling occurring in the center with the control lens and in the midperiphery with the test lenses (polynomial regression: P<0.005). Significantly greater central corneal swelling was found with the control lens than the test lens (6.9% +/- 3.1% vs. 4.9% +/- 2.0%, respectively, P=0.006). The effect on epithelial thickness differed between lenses and depended on both position and time (F(48,912)=2.3; P=0.000). Immediately after removal of the test lens, the central epithelium was 5.1% +/- 4.5% thinner than baseline, and all other locations (P<0.005 post hoc tests) and the epithelium in the midperiphery showed significant thickening (1.9% on the temporal side and 2.4% on the nasal side, both P<0.006 compared with the baseline). There were no significant changes in epithelial thickness with the control lens during the study period (post hoc tests: P>0.05). CONCLUSIONS: The optical coherence tomograph is a sensitive instrument that can detect small changes in epithelial and corneal thickness across the entire cornea. Topographical thickness changes of the epithelium and total cornea induced by one night of reverse-geometry lens wear appear to be associated with the decrease of myopia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.197
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.004
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.300
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it