MétaCan
Menu
Back to cohort

Correlation of transcutaneous hepatic near‐infrared spectroscopy readings with liver surface readings and perfusion parameters in a piglet endotoxemic shock model

2006· article· en· W2059459810 on OpenAlexaff
Elhanan Nahum, Peter Skippen, R. Gagnon, Anita Macnab, Erik D. Skarsgard

Bibliographic record

VenueLiver International · 2006
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsChildren's & Women's Health Centre of British ColumbiaUniversity of British Columbia
Fundersnot available
KeywordsMedicinePerfusionJugular veinBlood flowShock (circulatory)Septic shockSepsisVeinAnesthesiaCardiologyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To determine whether transcutaneous liver near-infrared spectrophotometry (NIRS) measurements correlate with NIRS measurements taken directly from the liver surface, and invasive blood flow measurements. PROCEDURE: Laparotomy was performed in 12 Yorkshire piglets, and ultrasound blood flow probes were placed on the hepatic artery and portal vein. Intravascular catheters were inserted into the hepatic and portal veins for intermittent blood sampling, and a pulmonary artery catheter was inserted via the jugular vein for cardiac output measurements. NIRS optodes were placed on skin overlying the liver and directly across the right hepatic lobe. Endotoxemic shock was induced by continuous infusion of Escherichia coli lipopolysaccharide O55:B5. Pearson's correlations were calculated between the NIRS readings and the perfusion parameters. FINDINGS: After endotoxemic shock induction, liver blood flow, and oxygen delivery decreased significantly. There were statistically significant correlations between the transcutaneous and liver-surface NIRS readings for oxyhemoglobin, deoxyhemoglobin, and cytochrome c oxidase concentrations. There were similar significant correlations of the transcutaneous oxyhemoglobin with both the mixed venous and hepatic vein saturation, and mixed venous and hepatic vein lactate. CONCLUSIONS: Transcutaneous NIRS readings of the liver, in an endotoxemic shock model, correlate with NIRS readings taking directly from the liver surface, as well as with global and specific organ-perfusion parameters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.894
Threshold uncertainty score0.576

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.242
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueLiver InternationalSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207