MétaCan
Menu
Back to cohort
Record W2060094384 · doi:10.1371/journal.pone.0000367

Evaluation of Diagnostic Accuracy, Feasibility and Client Preference for Rapid Oral Fluid-Based Diagnosis of HIV Infection in Rural India

2007· article· en· W2060094384 on OpenAlexaff
Nitika Pant Pai, Rajnish Joshi, Sandeep Dogra, Shriprakash Kalantri, Madhukar Pai, Jacqueline P. Tulsky, Arthur Reingold

Bibliographic record

VenuePLoS ONE · 2007
Typearticle
Languageen
FieldImmunology and Microbiology
TopicHIV Research and Treatment
Canadian institutionsMcGill UniversityMcGill University Health Centre
FundersFogarty International CenterUniversity of California, San Francisco
KeywordsMedicineHuman immunodeficiency virus (HIV)Confidence intervalTest (biology)PreferenceInternal medicineFamily medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based OraQuick Rapid HIV1/2 test in a rural hospital in India. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional, hospital-based study was conducted in 450 consenting participants with suspected HIV infection in rural India. The objectives were to evaluate performance, client preference and feasibility of the OraQuick Rapid HIV-1/2 tests. Two Oraquick Rapid HIV1/2 tests (oral fluid and finger stick) were administered in parallel with confirmatory ELISA/Western Blot (reference standard). Pre- and post-test counseling and face to face interviews were conducted to determine client preference. Of the 450 participants, 146 were deemed to be HIV sero-positive using the reference standard (seropositivity rate of 32% (95% confidence interval [CI] 28%, 37%)). The OraQuick test on oral fluid specimens had better performance with a sensitivity of 100% (95% CI 98, 100) and a specificity of 100% (95% CI 99, 100), as compared to the OraQuick test on finger stick specimens with a sensitivity of 100% (95% CI 98, 100), and a specificity of 99.7% (95% CI 98.4, 99.9). The OraQuick oral fluid-based test was preferred by 87% of the participants for first time testing and 60% of the participants for repeat testing. CONCLUSION/SIGNIFICANCE: In a rural Indian hospital setting, the OraQuick Rapid- HIV1/2 test was found to be highly accurate. The oral fluid-based test performed marginally better than the finger stick test. The oral OraQuick test was highly preferred by participants. In the context of global efforts to scale-up HIV testing, our data suggest that oral fluid-based rapid HIV testing may work well in rural, resource-limited settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.014
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.131
GPT teacher head0.334
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations65
Published2007
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONESame topicHIV Research and TreatmentFrench-language works237,207