MétaCan
Menu
Back to cohort
Record W2060324675 · doi:10.1118/1.2714473

Dose calculation validation of VMC++ for photon beams

2007· article· en· W2060324675 on OpenAlexaff
J Gardner, Jeffrey V. Siebers, I. Kawrakow

Bibliographic record

VenueMedical Physics · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNational Research Council Canada
FundersNational Cancer InstituteNational Institutes of Health
KeywordsImaging phantomVoxelMonte Carlo methodNuclear medicineDosimetryRadiation therapyRadiation treatment planningPhysicsMathematicsMedicineStatisticsRadiology

Abstract

fetched live from OpenAlex

The radiation therapy specific Voxel Monte Carlo (VMC+ +) dose calculation algorithm achieves a dramatic improvement in MC dose calculation efficiency for radiation therapy treatment planning dose evaluation compared with other MC algorithms. This work aims to validate VMC+ + for radiation therapy photon beam planning. VMC++ was validated with respect to the well-benchmarked EGS-based DOSXYZnrc by comparing depth dose and lateral profiles for field sizes ranging from 1 X 1 to 40 x 40 cm(2) for 6 and 18 MV beams in a homogeneous water phantom and in a simulated bone-lung-bone phantom. Patient treatment plan dose distributions were compared for five prostate plans and five head-and-neck (H/N) plans, all using intensity-modulated radiotherapy beams. For all tests, the same incident particles were used in both codes to isolate differences due to modeling of the radiation source. Voxel-by-voxel observed differences were analyzed to distinguish between systematic and purely statistical differences. Dose-volume-histogram-derived dose indices were compared for the patient plans. For the homogeneous water phantom and the bone-lung-bone phantom, the depth dose curve predicted by VMC+ + agreed with that predicted by DOSXYZnrc within expected statistical uncertainty in all voxels except the surface voxel of the water phantom, where VMC+ + predicted a lower dose. When the electron cutoff parameter was decreased for both codes, the surface voxel agreed within expected statistical uncertainty. For prostate plans, the most severe difference between the codes resulted in 55% of the voxels showing a systematic difference of 0.32% of maximum dose. For H/N plans, the largest difference observed resulted in 2% of the voxels showing a systematic difference of 0.98% of maximum dose. For the prostate plans, the most severe difference in the planning target volume D95 was 0.4%, the rectum D35 was 0.2%, the rectum DI7 was 0.2%, the bladder D50 was 0.3% and the bladder D25 was 0.3%. For the H/N plans, the most severe difference in the gross tumor volume D98 was 0.4%, the clinical target volume D90 was 0.2%, the nodes D90 was 0.2%, the parotids D95 was 0.8%, and the cord D2 was 0.8%. All of these differences are clinically insignificant. VMC++ showed an average efficiency gain over DOSXYZnrc of at least an order of magnitude without introducing significant systematic bias. VMC + + can be used for photon beam MC patient dose computations without a clinically significant loss in accuracy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.922
Threshold uncertainty score0.296

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.320
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207