MétaCan
Menu
Back to cohort
Record W2062720837 · doi:10.3415/vcot-09-05-0055

The effect of the combination of locking screws and non-locking screws on the torsional properties of a locking-plate construct

2009· article· en· W2062720837 on OpenAlexafffund
N M M Moens, John Runciman, G M Monteith, S Gordon

Bibliographic record

VenueVeterinary and Comparative Orthopaedics and Traumatology · 2009
Typearticle
Languageen
FieldMedicine
TopicBone fractures and treatments
Canadian institutionsUniversity of Guelph
FundersOVC Pet TrustMississippi State University
KeywordsTorsion (gastropod)Cadaveric spasmTorqueMedicineOrthodonticsStructural engineeringSurgeryPhysicsEngineering

Abstract

fetched live from OpenAlex

Little is known about the torsional properties of bone-plate constructs when a combination of locking and non-locking screws have been used. Sixty cadaveric canine femurs were divided into three groups. In the first group, the plate was affixed using three non-locking screws. In the second group, only locking screws were used while a combination of one locking and two non-locking screws were used in the third group. All constructs were subjected to torsion until failure. Torque, angle of torsion, and work were all calculated at the maximum failure point, as well as at five degrees of plastic deformation, which was thought to be more representative of clinical failure. At the maximum failure point, the locking group had significantly higher torque, angle, and work values than the non-locking group. The combination group was intermediate to the two other groups, and significantly differed from the non-locking group in torque, and from the locking group in work. At five degrees of plastic deformation, the locking group required significantly higher torque and work than the non-locking group. The combination group required a significantly higher torque than the non-locking group. This study suggests that a construct composed of all locking screws will fail at a greater torque value, and sustain greater work to failure in torsion compared to a construct composed of all non-locking screws. The addition of a single locking screw to an otherwise non-locking construct will increase the torque at the offset failure point and may be of clinical value in constructs subjected to high torsional loads.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.282
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueVeterinary and Comparative Orthopaedics and TraumatologySame topicBone fractures and treatmentsFrench-language works237,207