MétaCan
Menu
Back to cohort
Record W2064440302 · doi:10.1097/brs.0b013e31817c55e2

Validation of a Novel Minimally Invasive Intervertebral Disc Pressure Sensor Utilizing In-Fiber Bragg Gratings in a Porcine Model

2008· article· en· W2064440302 on OpenAlexaff
Christopher R. Dennison, Peter Wild, Marcel F. Dvorak, David R. Wilson, Peter A. Cripton

Bibliographic record

VenueSpine · 2008
Typearticle
Languageen
FieldMedicine
TopicSpine and Intervertebral Disc Pathology
Canadian institutionsVancouver Spine Surgery InstituteUniversity of British ColumbiaUniversity of Victoria
Fundersnot available
KeywordsMedicineFiber Bragg gratingPressure sensorBiomedical engineeringIntervertebral discOptical fiberNucleusCompression (physics)Strain gaugeNuclear medicineAnatomyMaterials scienceComposite materialOpticsPhysics

Abstract

fetched live from OpenAlex

STUDY DESIGN: Nucleus pressure was measured within porcine intervertebral discs (IVDs) with a novel in-fiber Bragg grating (FBG) sensor (0.4 mm diameter) and a strain gauge (SG) sensor (2.45 mm). OBJECTIVE: To validate the accuracy of a new FBG pressure sensor designed for minimally invasive measurements of nucleus pressure. SUMMARY OF BACKGROUND DATA: Although its clinical utility is controversial, it is possible that the predictive accuracy of discography can be improved with IVD pressure measurements. These measurements are typically obtained using needle-mounted SG sensors inserted into the nucleus. However, by virtue of their size, SG sensors alter disc mechanics, injure anulus fibers, and can potentially initiate or accelerate degenerative changes thereby limiting their utility particularly clinically. METHODS: Six functional spinal units were loaded in compression from 0 N to 500 N and back to 0 N; nucleus pressure was measured using the FBG and SG sensors at various locations along anterior and anterolateral axes. RESULTS: On average maximum IVD pressures measured using the FBG and SG sensors were within 9.39% of each other. However, differences between maximum measured pressures from the FBG and SG sensors were larger (22.2%) when the SG sensor interfered with vertebral endplates (P < 0.05). The insertion of the FBG sensor did not result in visible damage to the anulus, whereas insertion of the SG sensor resulted in large perforations in the anulus through which nucleus material was visible. CONCLUSION: The new FBG sensor is smaller and less invasive than any previously reported disc pressure sensor and gave results consistent with previous disc pressure studies and the SG sensor. There is significant potential to use this sensor during discography while avoiding the controversy associated with disc injury as a result of sensor insertion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.302
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpine and Intervertebral Disc PathologyFrench-language works237,207