Record W2064951370 · doi:10.1016/j.arthro.2009.12.009

A Comparison of Knot Security and Loop Security in Arthroscopic Knots Tied With Newer High‐Strength Suture Materials

2010· article· en· W2064951370 on OpenAlexaff
Ian K.Y. Lo, Eloy Ochoa, Stephen S. Burkhart

Bibliographic record

VenueArthroscopy The Journal of Arthroscopic and Related Surgery · 2010
Typearticle
Languageen
FieldMedicine
TopicSurgical Sutures and Adhesives
Canadian institutionsUniversity of Calgary
FundersArthrex
KeywordsKnot (papermaking)Fibrous jointComputer scienceOrthodonticsSurgeryMedicineMaterials scienceGeologyComposite material

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of this study was to compare the knot security and loop security of 2 sliding and 1 static arthroscopic knot tied with different types of suture material. METHODS: We evaluated 3 commonly used arthroscopic knots (surgeon's knot, Roeder knot, and Weston knot) tied with 6 different braided No. 2 sutures (FiberWire [Arthrex, Naples, FL]; Ethibond [Ethicon, Somerville, NJ]; Orthocord [DePuy Mitek, Raynham, MA]; Herculine [now called HiFi; ConMed Linvatec, Largo, FL]; MaxBraid [Arthrotek, Warsaw, IN]; and UltraBraid [Smith & Nephew, Andover, MA]). Each suture loop was then mounted on a materials testing system, and its circumference was measured at a 5-N preload to assess each knot's ability to maintain a tight suture loop without slippage (loop security). Knot security was measured as the maximum force to failure at 3 mm of crosshead displacement or suture breakage during single-pull load testing. RESULTS: We found that tying knots with different types of suture material can affect both the knot security and loop security of various types of arthroscopic knots. When a Roeder knot or surgeon's knot was tied, No. 2 FiberWire had the highest force to failure when compared with similar knots tied with other suture material (P < .001). The loop security for many of the knot and suture configurations was not significantly different. However, No. 2 FiberWire consistently showed the smallest loop circumference when compared with other suture materials. CONCLUSIONS: Arthroscopic knots tied with No. 2 FiberWire provide superior knot security and similar loop security compared with other commonly used high-strength polyethylene suture materials. CLINICAL RELEVANCE: High-strength sutures exhibit unique mechanical characteristics that may vary significantly between suture types. In addition, knot configuration plays an important role in altering these characteristics as they relate to knot security.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0020.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.271
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations44
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueArthroscopy The Journal of Arthroscopic and Related SurgerySame topicSurgical Sutures and AdhesivesFrench-language works237,207