MétaCan
Menu
Back to cohort
Record W2065694695 · doi:10.1088/0031-9155/52/4/017

Delineation of moving targets with slow MVCT scans: implications for adaptive non-gated lung tomotherapy

2007· article· en· W2065694695 on OpenAlexaff
Christopher Smeenk, Stewart Gaede, Jerry Battista

Bibliographic record

VenuePhysics in Medicine and Biology · 2007
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsWestern UniversityCancer Care Ontario
Fundersnot available
KeywordsTomotherapyMedical physicsMedicineNuclear medicineComputer scienceRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

Accurate imaging is a prerequisite for adaptive radiation therapy of mobile tumours. We present an evaluation of the performance of slow computed tomography (CT) for mapping and delineating the excursion boundary of a moving object using a tumour phantom scanned with the helical MVCT scanner of a tomotherapy unit. A spherical test object driven by sinusoidal motion in both the lateral and cranial-caudal directions was used to determine how well MVCT images depict the true envelope of the motion. Such information is useful in interpreting the CT images relative to the static object case when radiotherapy gating is to be used or in determining the internal target volume (ITV) when beam gating is not possible. A computer simulation of the CT imaging process was developed which incorporates the third generation fan beam geometry and helical acquisition technique of the tomotherapy MVCT system. Motion artefacts are mainly characterized by the parameter alpha=Tgantry/Trespiration which is interpreted as the period of the gantry rotation (Tgantry) in units of the respiratory period (Trespiration). Experimental tests were performed using a fixed gantry period of 10 s per full rotation and respiratory period ranging from 4.0 (alpha=2.5) to 1.0 (alpha=10) s. These cases represent typical clinical imaging conditions on the tomotherapy unit, as well as an extreme test case where the gantry period is intentionally set to be much greater than the respiratory period (termed an 'ultra-slow' scan). The accuracy of target (ITV) delineation is evaluated by comparing volumes generated using iso-density contours on the MVCT images to the true motion envelope, known a priori in this phantom study. As expected, motion artefacts are present in clinical MVCT images and they are not averaged over the slow gantry period of rotation. Furthermore, artefacts are not significantly affected by scanning with different helical pitch values. Greater distortions from the true density distribution are observed for lateral motion compared to cranial-caudal motion. Volumes generated by iso-density contours yield better agreement with the motion envelope for scans performed under ultra-slow conditions (alpha=10) compared to typical clinical imaging conditions (alpha=2.5). If the MVCT gantry cannot be rotated very quickly due to engineering constraints in order to achieve ultra-fast CT, we suggest an opposite approach as an interim measure for mapping the ITV. Adjusting MVCT scan conditions to a very slow acquisition (alpha=10) may be a good compromise for determining the ITV for non-gated adaptive tomotherapy of moving lung tumours.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.395
Teacher spread0.329 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2007
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207