MétaCan
Menu
Back to cohort
Record W2066302130 · doi:10.1021/ac103216s

Universal Method for Determining Electrolyte Temperatures in Capillary Electrophoresis

2011· article· en· W2066302130 on OpenAlexaff
Christopher J. Evenhuis, Michael U. Musheev, Sergey N. Krylov

Bibliographic record

VenueAnalytical Chemistry · 2011
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsYork University
Fundersnot available
KeywordsCapillary electrophoresisElectrolyteCapillary actionChemistryJoule heatingVoltageAnalytical Chemistry (journal)Universality (dynamical systems)Current (fluid)Range (aeronautics)ChromatographyMechanicsThermodynamicsElectrodeMaterials scienceElectrical engineeringPhysics

Abstract

fetched live from OpenAlex

Temperature increase in capillary electrophoresis (CE) due to Joule heating is an inherent limitation of this powerful separation technique. Active cooling systems can decrease the temperature of a large part of the capillary but they leave "hot spots" at the capillary ends which can completely ruin some CE analyses despite their short lengths. Here, we introduce a "universal method for determining electrolyte temperatures" (UMET) that can determine temperatures in both efficiently- and inefficiently-cooled parts of the capillary. UMET can be applied to all electrolytes, as it does not involve any probe; it requires only measuring current versus voltage for different voltages and processing the data using an iterative algorithm. To demonstrate the universality of UMET, we measured temperatures for electrolytes of different ionic strengths as well as for different capillary diameters. We further propose a "simplified universal method for predicting electrolyte temperatures" (SUMET) which only requires one measurement of current and voltage (that can be completed in 1 min) and uses two empirical equations to predict temperatures in the efficiently- and inefficiently-cooled parts of the capillary. The equations include several instrument-specific empirical parameters that are determined using a large set of current-voltage data obtained with UMET for a range of electrolytes and different capillaries. To demonstrate the utility of SUMET, we obtained the required data set for a Beckman MDQ CE instrument and produced all required empirical parameters that enable a user of this instrument to predict the temperature for every new experimental set in a matter of minutes. We confirmed the accuracy of SUMET by measuring the temperature-sensitive dissociation rate constant of a protein-DNA complex. We foresee that UMET will be used to produce instrument-specific empirical parameters for all CE instruments and then SUMET will be routinely used for temperature prediction in CE.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.007
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.002
Open science0.0030.002
Research integrity0.0010.003
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.227
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207