MétaCan
Menu
Back to cohort
Record W2066525182 · doi:10.1117/12.921644

Diode laser based photoacoustic gas measuring instruments intended for medical research

2012· article· en· W2066525182 on OpenAlexfundno aff
Anna Szabó, Árpád Mohácsi, Péter Novák, Daniela Aladzic, Kinga Turzó, Zoltán Rakonczay, Gábor Erős, Mihály Boros, Katalin Nagy, Gábor Szabó

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2012
Typearticle
Languageen
FieldChemistry
TopicSpectroscopy and Laser Applications
Canadian institutionsnot available
FundersFaculty of Medicine and Dentistry, University of AlbertaSzegedi Tudományegyetem
KeywordsPhotoacoustic imaging in biomedicineLaserDiodeMaterials scienceOptoelectronicsComputer scienceOpticsPhysics

Abstract

fetched live from OpenAlex

Analysis of breath and gases emanated from skin can be used for early and non-invasive diagnosis of various kinds of diseases. Two portable, compact, photoacoustic spectroscopy based trace gas sensors were developed for the detection of methane emanated from skin and ammonia emanated from oral cavity. The light sources were distributed feedback diode lasers emitting at the absorption lines of ammonia and methane, at 1.53 μm and 1.65 μm, respectively. Photoacoustic method ensures high selectivity, therefore cross-sensitivity was negligible even with large amount of water vapor and carbon dioxide in the gas sample. In case of ammonia a preconcentration unit was used to achieve lower minimum detectable concentration. Gas sample from the oral cavity was drawn through a glass tube to the preconcentration unit that chemically bonded ammonia and released it when heated. The minimum detectable concentration of ammonia was 10 ppb for 15 s gas sampling time (gas sample of 250 cm3). For methane minimum detectable concentration of 0.25 ppm was found with 12 s integration time, and it was proved to be adequate for the detection of methane emanated from human skin and from mice. Instruments measuring methane and ammonia are currently installed at two medical research laboratories at University of Szeged and tested as instruments for non-invasive clinical trials. The aim of the measurements is to determine correlations between diseases or metabolic processes and emanated gases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.007
Threshold uncertainty score0.024

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0070.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.285
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicSpectroscopy and Laser ApplicationsFrench-language works237,207