MétaCan
Menu
Back to cohort
Record W2067035933 · doi:10.1063/1.4898637

Piezoelectric layer embedded-microdiaphragm sensors for the determination of blood viscosity and density

2014· article· en· W2067035933 on OpenAlexaff
Hye Jin Kim, Jinsik Kim, Omid Zandieh, Myung-Sic Chae, Tae Song Kim, Jeong Hoon Lee, Jung Ho Park, Seonghwan Kim, Kyo Seon Hwang

Bibliographic record

VenueApplied Physics Letters · 2014
Typearticle
Languageen
FieldEngineering
TopicAcoustic Wave Resonator Technologies
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsViscosityAnalytical Chemistry (journal)Materials sciencePolydimethylsiloxaneLead zirconate titanatePiezoelectricityRange (aeronautics)ChemistryComposite materialChromatographyOptoelectronicsFerroelectricity

Abstract

fetched live from OpenAlex

We introduce a lead zirconate titanate [PZT; Pb(Zr0.52Ti0.48)O3] microdiaphragm resonating sensor packaged in a polydimethylsiloxane chip. The proposed sensor can measure the density and viscosity of a liquid that is within the density and viscosity regime of blood (1.060 × 103 kg/m3, 3–4 cP). To verify the basic characteristics of the sensor, viscous solutions were prepared from glycerol and deionized water with a density in the range from 0.998 to 1.263 × 103 kg/m3 and a viscosity in the range from 1 to 1414 cP. We measured the frequency responses of the sensor before and after injecting the viscosity- and density-controlled liquid under the bottom of the microdiaphragm. The resonant frequencies in the (1,1) and (2,2) modes decreased linearly as a function of the liquid density in the range from 0.998 to 1.146 × 103 kg/m3 with a sensitivity of 28.03 Hz/kg·m−3 and 81.85 Hz/kg·m−3, respectively. The full width at half maximum had a logarithmic relationship with the liquid viscosity in the viscosity range from 1 to 8.4 cP. The quality factor (Q-factor) for the 50% glycerol/water mixture was determined to be greater than 20 for both the (1,1) and the (2,2) modes, indicating that the microdiaphragm resonating sensor is suitable for measuring the density and viscosity of a liquid within a density range from 0.998 to 1.1466 × 103 kg/m3 and a viscosity range from 1 to 8.4 cP. These density and viscosity ranges span the regime of possible changes of blood characteristics. The microdiaphragm resonating sensors were also tested with a real human serum to verify that the sensor is suitable for measuring the viscosity and density of blood. Therefore, the PZT microdiaphragm resonating sensor could be utilized for early diagnosis of diseases associated with changes in the physical properties of blood.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.194
Teacher spread0.187 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueApplied Physics LettersSame topicAcoustic Wave Resonator TechnologiesFrench-language works237,207