An Evaluation of a Novel Software Tool for Detecting Changes in Physiological Monitoring

2009· article· en· W2068762597 on OpenAlexaff
J. Mark Ansermino, Jeremy Daniels, Randy T. Hewgill, Joanne Lim, Ping Yang, Chris J. Brouse, Guy A. Dumont, John Bowering

Bibliographic record

VenueAnesthesia & Analgesia · 2009
Typearticle
Languageen
FieldMedicine
TopicHealthcare Technology and Patient Monitoring
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicineSoftwareCUSUMSimulationStatisticsComputer science

Abstract

fetched live from OpenAlex

BACKGROUND: We have developed a software tool (iAssist) to assist clinicians as they monitor the physiological data that guide their actions during anesthesia. The system tracks the statistical properties of multiple dynamic physiological processes and identifies new trend patterns. We report our initial evaluation of this tool (in pseudo real-time) and compare the detection of trend changes to a post hoc visual review of the full trend. We suggest a combination of criteria by which to evaluate the performance of monitoring devices that aim to enhance trend detection. METHODS: Nineteen children and 28 adults consented to be included in the study, encompassing more than 68 h of anesthesia. In each surgical case, an anesthesiologist reported all perceived clinical changes in monitoring in real-time. A trained observer simultaneously documented the verbally reported changes and every anesthesiologist action. The same cases were subsequently evaluated offline (in pseudo real-time) by a novel software tool (iAssist). Heart rate, end-tidal carbon dioxide, exhaled minute ventilation, and respiratory rate were modeled using a dynamic linear growth model whose noise distribution was estimated by an adaptive Kalman filter based on a recursive expectation-maximization method. Changes were detected by adaptive local Cumulative Sum testing. Changes in the mean arterial noninvasive blood pressures and oxygen saturation were detected using adaptive Cumulative Sum testing on a filtered residual from an exponentially weighted moving averaging filter. In post hoc analysis, each change detected by iAssist was graded independently by two clinicians using a graphical display of the whole case. Missed changes were recorded. RESULTS: The iAssist software tool detected 869 true positive changes (at an average of 12.76/h) with a sensitivity of 0.91 and positive predictive value of 0.87. The post hoc review identified 91 missed changes (at an average of 1.34/h), resulting in an overall ratio of true positive rates to false-negative rates of 9.55. The clinicians in real-time reported 209 changes in trend (at an average of 3.07/h). CONCLUSION: The algorithms perform favorably compared with a visual inspection of the complete trend. Further research is needed to identify when and how to draw the clinician's attention to these changes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.022
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.034

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.022
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.382
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueAnesthesia & AnalgesiaSame topicHealthcare Technology and Patient MonitoringFrench-language works237,207