MétaCan
Menu
Back to cohort
Record W2069449487 · doi:10.1021/ac060485v

Nonretentive Solid-Phase Extraction of Phosphorylated Peptides from Complex Peptide Mixtures for Detection by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

2006· article· en· W2069449487 on OpenAlexafffund
Petra Kapková, Erika Lattová, Hélène Perreault

Bibliographic record

VenueAnalytical Chemistry · 2006
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of Manitoba
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryChromatographyMass spectrometryPhosphopeptideSolid phase extractionIon suppression in liquid chromatography–mass spectrometrySample preparationExtraction (chemistry)PeptideDesorptionMatrix-assisted laser desorption/ionizationPolystyreneTandem mass spectrometryAdsorptionBiochemistryPolymerOrganic chemistry

Abstract

fetched live from OpenAlex

Widespread interest in protein phosphorylation has led to the development of a variety of methods for the analysis of phosphoproteomes of different types of organisms. Many applications involve pretreatment of the sample before mass spectrometric measurement and can crucially improve the detection efficiency of individual phosphopeptides. Despite intense research efforts, separation and extraction of phosphorylated peptides, especially multiphosphorylated ones, remain challenging tasks and need to be further explored and expanded with unconventional approaches. In this study, we describe the application of nonretentive solid-phase extraction (SPE) to the analysis of phosphopeptides using the highly cross-linked polystyrene-divinylbenzene material Strata-X. This study indicates that the procedure allows for the preferential extraction of phosphopeptides regardless of their extent of phosphorylation. The Strata-X material primarily retains nonphosphorylated peptides by hydrophobic interaction, whereas the inherent hydrophilicity of phosphorylated peptides leads to their partitioning into the aqueous phase. Phosphopeptides that were rapidly segregated out of tryptic digest mixtures and collected in the early aqueous fractions generated intense signals in mass spectra. The method was developed using SPE Strata-X columns, then suited for detection and sequencing of phosphopeptides by miniaturizing the system to the scale of custom-made microcolumns. This provided fast isolation of phosphopeptides from protein digests along with direct MALDI on-target deposition. The possibility of on-target washing during sample preparation is also presented.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.315
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2006
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207