Fabrication of an SU-8 based microfluidic reactor on a PEEK substrate sealed by a flexible semi-solid transfer (FST) process
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
A continuous flow polymeric microfluidic reactor utilizing SU-8 as a photoresist on a PEEK (polyetheretherketone) substrate was fabricated by standard UV lithography. Embedded multilayer structures were fabricated between the substrate and the inlets and outlet of the microfluidic reactor that facilitated fabrication of the entire microfluidics using SU-8, resulting in improved bonding between the substrate and the pattern. A 'flexible semi-solid transfer' (FST) process, based on a reduced exposure dosage, was developed to seal the microfluidic channels. Scanning electron microscopy (SEM) images and photographs revealed no trace of blockages in channels due to the sealing process. The maximum pressure drop without any leakage was found to be 2.1 MPa. The microfluidic reactor withstood temperatures as high as 150 °C and was found to be suitable for carrying out wet chemical synthesis.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it