MétaCan
Menu
Back to cohort
Record W2070199107 · doi:10.1002/uog.7750

How best to measure the levator hiatus: evidence for the non‐Euclidean nature of the ‘plane of minimal dimensions’

2010· article· en· W2070199107 on OpenAlexaff
Jennifer Kruger, STUART W. HEAP, B. A. Murphy, H. P. Dietz

Bibliographic record

VenueUltrasound in Obstetrics and Gynecology · 2010
Typearticle
Languageen
FieldMedicine
TopicPelvic floor disorders treatments
Canadian institutionsOntario Tech University
Fundersnot available
KeywordsCoronal planeTransverse planeMedicineAnatomyUltrasound3D ultrasoundMagnetic resonance imagingTransverse diameterValsalva maneuverNuclear medicineRadiology

Abstract

fetched live from OpenAlex

OBJECTIVE: To clarify whether the 'plane of minimal dimensions' of the levator hiatus on three-dimensional (3D) ultrasound accurately represents the minimal anatomical transverse hiatal dimension during a Valsalva maneuver. METHODS: In this retrospective study of 3D transperineal ultrasound and magnetic resonance (MR) imaging, datasets from 19 female participants were used to measure the transverse diameter of the levator hiatus using the plane of minimal dimensions on maximum Valsalva maneuver. The term 'apparent minimal transverse diameter' (aMTD) was used to define the transverse diameter measured using axial ultrasound and comparable axial or coronal MR images. Coronal MR images, using the plane of the vagina as a reference, were also obtained on maximum Valsalva. The transverse diameter measured between the caudal margin of the pubococcygeus/puborectalis on the MR coronal image is denoted by the term 'true minimal transverse diameter' (tMTD). Statistical comparisons between the aMTD and tMTD were made using Student's t-test. RESULTS: No significant difference was demonstrated between the aMTD as measured by ultrasonography and MRI. However, there were significant differences found between the aMTD measured by both ultrasound and MRI and the tMTD measured on coronal MR images (both P < 0.01), with mean ( ± SD) values of 4.36 ± 0.85, 4.13 ± 1.09 and 3.23 ± 0.49 cm, respectively. CONCLUSION: This study highlights the complexity and 3D nature of the levator hiatus and pelvic floor muscles. Investigators have previously assumed that the plane of minimal dimensions of the hiatus can be measured in a flat plane, however, the 3D nature of the hiatus means that the true levator hiatus occupies a warped (non-Euclidean) plane. Hiatal measurements on Valsalva may be subject to systematic error if performed in a single section, i.e. using a flat (Euclidean) plane.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.031
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.031
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.284
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueUltrasound in Obstetrics and GynecologySame topicPelvic floor disorders treatmentsFrench-language works237,207