MétaCan
Menu
Back to cohort

Laser Lead Extraction: Predictors of Success and Complications

2007· article· en· W2070243203 on OpenAlexaffabout
Jean-François Roux, Pierre Pagé, Marc Dubuc, Bernard Thibault, Peter G. Guerra, Laurent Macle, Denis‐Claude Roy, Mario Talajic, Paul Khairy

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2007
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMontreal Heart Institute
Fundersnot available
KeywordsMedicineEndocarditisSurgeryLead (geology)ImplantPercutaneousMultivariate analysisStyletCardiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Paralleling the rise in pacemaker and defibrillator implantations, lead extraction procedures are increasingly required. Concerns regarding failure and complications remain. METHODS AND RESULTS: A total of 200 lead extraction procedures were performed at the Montreal Heart Institute between September 2000 and August 2005. In 23 patients, all leads were removed by traction with a locking stylet. A total of 270 leads were extracted using a laser sheath system (Spectranectics, Colorado Springs, CO, USA) in 177 procedures involving 175 patients (74% male), age 62+/-16 years. Procedural indications were: infection 88 (50%), dysfunction 54 (30%), upgrade 21 (12%), and other 14 (8%). Overall, 241 leads (89%) were successfully extracted, 7 (3%) were partially extracted (< or = 4 cm retained), and 22 (8%) were non-extractable. In multivariate analyses, predictors of failed extraction were longer time from implant (OR 1.16 per year, P=0.0001) and history of hypertension (OR 5.2, P=0.0023). Acute complications occurred in 14 of 177 procedures (7.9%): 8 (4.5%) minor and 6 (3.4%) major, with one death. In multivariate analyses, the only predictor of acute complications was laser lead extraction from both right and left sides during the same procedure (OR 9.4, P = 0.0119). In addition, 3 of 10 patients with failed or partially extracted infected systems eventually required open chest explantation because of endocarditis. CONCLUSION: Most leads not amenable to manual traction may be successfully extracted by a percutaneous laser sheath system. While most complications are minor, major complications including death may occur. Older leads are at higher risk for failed extraction. Endocarditis may ensue if infected leads are incompletely removed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.136
Threshold uncertainty score0.258

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.387
Teacher spread0.358 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations106
Published2007
Admission routes2
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207