<b>Biocompatibility Studies of the Anaconda Stent-Graft and Observations of Nitinol Corrosion Resistance</b>
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
PURPOSE: To validate the deployment, in vivo performance, biostability, and healing capacity of the Anaconda self-expanding endoprosthesis in a canine aortic aneurysm model. METHODS: Aneurysms were surgically created in 12 dogs by sewing a woven polyester patch onto the anterior side of the thoracic or abdominal aorta. Anaconda prostheses were implanted transfemorally for prescheduled periods (1 or 3 months). Aneurysm exclusion and stent-graft patency were monitored angiographically. Healing was assessed with histological analysis and scanning electron microscopy (SEM). Textile analysis determined the physical and chemical stability of the woven polyester material, while the biostability of the nitinol wires was evaluated with SEM and spectroscopy. RESULTS: All prostheses were intact at explantation. After 1 month, endothelial-like cells were migrating in a discontinuous manner both proximally and distally over the internal collagenous pannus at the device-host boundary. After 3 months, endothelialization had reached the midsections of the devices, with a thicker collagenous internal capsule. Patches of endothelial-like cells were sharing the luminal surface with thrombotic deposits. However, the wall of the device at the level of the aneurysm was generally poorly healed, with multiple thrombi scattered irregularly over the luminal surface. The polyester fabric was intact except for some filaments that were ruptured adjacent to the sutures and some abrasion caused by the nitinol wires. No evidence of corrosion was found on the nitinol stents. CONCLUSIONS: This Anaconda stent-graft has demonstrated its ability to exclude arterial aneurysms. The device used in this study was an experimental prototype, and the manufacturer has incorporated new immobilization features into the model for clinical use. The constituent materials appear to be suitable in terms of biocompatibility, biofunctionality, and short-term durability.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it